Regarding connecting to AWS IoT Core Using the TCP Protocol
Because the AWS IoT Core specification is the TLS protocol, you cannot connect using the TCP protocol. More Details >>
- No:44344
- Release Date:2024/03/20 13:37
-
Regarding simultaneous execution of the MQTT communication function
The MQTT communication function cannot publish and subscribe at the same time. A program for the MQTT communication function is created using FB, but it c... More Details >>
- No:44345
- Release Date:2024/03/27 15:25
-
Regarding multiple connections for the MQTT communication function
The MQTT communication function of FX5-ENET does not allow multiple connections to be opened at the same time. The MQTT communication function has a maximum ... More Details >>
- No:44358
- Release Date:2024/03/27 16:02
-
Regarding using the MQTT Communication function in a local environment
Yes, you can use MQTT communication function even in the local network by preparing a personal computer with MQTT broker such as Eclipse Mosquitto installed.... More Details >>
- No:44367
- Release Date:2024/03/27 16:46
-
Regarding compatible version of CANopen communication function for PDO communication
It is necessary to use the following CPU module, FX5-CCLGN-MS, GX Works3 versions. FX5-CCLGN-MS・・・1.020 or later FX5U/FX5UC CPU module ・・・1.260 or later ... More Details >>
- No:44473
- Release Date:2024/07/02 19:06
-
The batch setting of PDO mapping sets the default PDO mapping for all device stations that support PDO mapping. *Note that in the batch setting of PDO mappi... More Details >>
- No:44476
- Release Date:2024/07/02 19:06
-
Regarding number of servo amplifiers that can be connected via PDO communication
The maximum number of servo amplifiers connected to the FX5-CCLGN-MS varies according to the number of axes. Example: When connecting a 3-axis servo amplifi... More Details >>
- No:44478
- Release Date:2024/07/02 19:07
-
Regarding Error code of FX5-ENET Mail send FB: H210
The following ranges overlap. Or the range of file register (R) used has been exceeded. Check whether the file register (R) is exceeded or not. ・area of de... More Details >>
- No:44608
- Release Date:2024/11/28 16:11
-
Regarding the system configuration of FX5-CCL-MS with FX5 CPU module
A total of two FX5-CCL-MS (CC-Link system master/intelligent device) can be connected: one as a master station and one as an intelligent device station. More Details >>
- No:22318
- Release Date:2018/08/30 13:55
- Update:2023/07/03 11:50
-
Regarding model name of CC-Link cables
The CC‐Link cables are being produced by various manufacturers, and no specific cable model is recommended. Please use a cable certified by the CC-Link Asso... More Details >>
- No:22330
- Release Date:2018/08/30 13:55
- Update:2023/07/03 11:53