Regarding display of FX5-ENET/IP in a Module configuration Diagram
Please update GX Works3 to the latest version. After updating, FX5-ENET/IP is displayed in the Module configuration diagram of GX Works3. Download the lates... More Details >>
- No:39303
- Release Date:2023/01/12 17:13
-
Regarding the MQTT Communication Function Publish Program
You can't program it with the ladder program alone. To use the MQTT communication and email functions, you must use the module FB and program it. More Details >>
- No:40051
- Release Date:2023/08/25 11:48
-
Regarding model name of CC-Link cables
The CC‐Link cables are being produced by various manufacturers, and no specific cable model is recommended. Please use a cable certified by the CC-Link Asso... More Details >>
- No:22330
- Release Date:2018/08/30 13:55
- Update:2023/07/03 11:53
-
Reagrding specifying an FTP client domain
The iQ-F series does not support domain specification, so specify the IP address. More Details >>
- No:44359
- Release Date:2024/03/27 15:58
-
Regarding Selecting a mapping pattern for PDO communication
On the FX5-CCLGN-MS, select "3rd Transmit PDO Mapping" and "3rd Revive PDO Mapping." The 3rd mapping pattern corresponds to the profile position mode (pp), ... More Details >>
- No:44477
- Release Date:2024/07/02 19:06
-
Regarding number of servo amplifiers that can be connected via PDO communication
The maximum number of servo amplifiers connected to the FX5-CCLGN-MS varies according to the number of axes. Example: When connecting a 3-axis servo amplifi... More Details >>
- No:44478
- Release Date:2024/07/02 19:07
-
CC-Link IE field When a network such as Network Basic is interrupted, the CPU module does not stop and continues to run. When the CC-Link IE Field Network i... More Details >>
- No:44611
- Release Date:2024/11/28 16:11
-
Regarding number of CC-Link IE field network Basic connections
When the FX5 CPU Module is used as the master station, the maximum number of devices connected to 1 network is 16. The following firmware versions are requi... More Details >>
- No:44652
- Release Date:2025/03/18 10:22
-
Regarding CC-Link IE Field Network Basic Communication Between FX5 CPU Modules
Since the FX5 CPU modules only support the master function, CC-Link IE Field Network Basic communication between FX5 CPU modules is not possible. More Details >>
- No:39297
- Release Date:2023/02/13 16:38
-
Regarding simultaneous access to Web Server function
The Web server function allows you to log in from up to four devices at the same time. You can't log in from the fifth machine. More Details >>
- No:39330
- Release Date:2023/02/14 09:06