FAQ within [ Network/Communication ]
-
Regarding display of FX5-ENET/IP in a Module configuration Diagram
Please update GX Works3 to the latest version. After updating, FX5-ENET/IP is displayed in the Module configuration diagram of GX Works3. Download the lates... More Details >>
- No:39303
- Release Date:2023/01/12 17:13
-
Regarding CC-Link IE Field Network Basic Communication Between FX5 CPU Modules
Since the FX5 CPU modules only support the master function, CC-Link IE Field Network Basic communication between FX5 CPU modules is not possible. More Details >>
- No:39297
- Release Date:2023/02/13 16:38
-
Regarding the simultaneous use of Simple CPU Communication and FX5-CCLGN-MS MELSOFT Connection
Can be used simultaneously. More Details >>
- No:39285
- Release Date:2023/01/12 16:50
-
Regarding the maximum number of connections for MODBUS communication
32 stations can be connected when RS-485 port is used and only 1 station can be connected when RS-232 port is used. More Details >>
- No:22324
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:49
-
Regarding expansion of communication ports
It is possible to use the MODBUS serial communication with multiple channels. However, only 1 channel can be set as the master. The MODBUS serial communica... More Details >>
- No:22323
- Release Date:2018/08/30 13:55
- Update:2023/06/26 09:04
-
Regarding communication supported by built-in RS-485 port
N:N Network, Parallel Link, MC protocol, Non-protocol communication, MELSOFT connection, MODBUS RTU, and Predefined protocol support are available. More Details >>
- No:22322
- Release Date:2018/08/30 13:55
- Update:2022/12/22 10:16
-
Yes, it is possible. Please consider functions such as Simple CPU communication or socket communication. More Details >>
- No:22294
- Release Date:2018/08/30 13:55
- Update:2022/12/22 10:00
-
Regarding TPDO and RPDO allocation
RWr is allocated to TPDO and RWw is allocated to RPDO. More Details >>
- No:44479
- Release Date:2024/07/02 19:06
-
Regarding compatible version of CANopen communication function for PDO communication
It is necessary to use the following CPU module, FX5-CCLGN-MS, GX Works3 versions. FX5-CCLGN-MS・・・1.020 or later FX5U/FX5UC CPU module ・・・1.260 or later ... More Details >>
- No:44473
- Release Date:2024/07/02 19:06
-
Regarding sending files in an SD Memory Card by Mail
Yes, as long as the capacity is expandable to the file register (R), it can be transmitted by using the file operation instruction. When sending, please set... More Details >>
- No:44369
- Release Date:2024/03/27 16:41