Regarding checking the input/output data of the FX5-EIP
This can be checked by monitoring the corresponding buffer memory from the Register to Intelligent Function Module Monitor. From [Parameter] - [Module Infor... More Details >>
- No:45490
- Release Date:2025/05/08 09:08
- Update:2025/10/31 15:18
-
Regarding PDO Mapping Settings
PDO mapping is configured from the CC-Link IE TSN configuration settings. ① Open the CC-Link IE TSN configuration settings from the FX5-CCLGN-MS Basic Set... More Details >>
- No:44475
- Release Date:2024/07/02 19:07
-
Regarding CC-Link IE TSN CANopen Communication function
The CANopen communication functions supported by the FX5-CCLGN-MS conform to the CiA402 CANopen profile, and can control devices that support the CiA402 devi... More Details >>
- No:44474
- Release Date:2024/07/02 19:07
-
Regarding Free Mail Service with Email Function
Free mail services that have been verified to work with the email function are Gmail, Yahoo! mail, and iCloud email.(As of July 2025) Use the encryption fun... More Details >>
- No:40058
- Release Date:2023/08/25 10:22
- Update:2025/11/11 14:31
-
Regarding the Number of Sending Addresses for Email function
The FX5-ENET module parameter of GX Works3 can send up to 10 messages and the module FB can send up to 256 characters at a time. By entering multiple email ... More Details >>
- No:40052
- Release Date:2023/08/25 10:23
-
Regarding nesting contacts displayed on bus by master control instructions
It is not possible. More Details >>
- No:39361
- Release Date:2023/02/15 13:04
-
Regarding the difference between the RS-485 expansion adapter and the extension board
The difference is the maximum transmission distance and the presence/absence of insulation (between the communication line and the CPU). ・Expansion Adapter ... More Details >>
- No:39315
- Release Date:2023/01/12 16:56
-
Regarding CC-Link IE Field Network Basic Communication Between FX5 CPU Modules
Since the FX5 CPU modules only support the master function, CC-Link IE Field Network Basic communication between FX5 CPU modules is not possible. More Details >>
- No:39297
- Release Date:2023/02/13 16:38
-
Regarding expansion of communication ports
MODBUS serial communication over multiple communication channels is possible. The MODBUS serial communication settings can be set from GX Works3 parameters. More Details >>
- No:22323
- Release Date:2018/08/30 13:55
- Update:2025/11/11 14:20
-
Regarding the connection configuration of FX5-CCL-MS
Connection is not allowed. For FX5-CCL-MS, only remote I/O stations, remote device stations andintelligent device stationscan be connected. More Details >>
- No:22316
- Release Date:2018/08/30 13:55
- Update:2023/07/03 17:19