Regarding the connection between FX5-CCLGN-MS and SLMP-compatible devices
The SLMP communication frames supported by the FX5-CCLGN-MS are 3E and 4E frames. When SLMP communication is performed from an SLMP-compatible device to the... More Details >>
- No:39280
- Release Date:2023/01/12 16:48
-
Regarding the change of settings for reserved station (master station) of FX5-CCLGN-MS
FX5-CCLGN-MS allows the master station to change the reserved station setting with parameters, but the setting can not be changed by program. Note that link... More Details >>
- No:39275
- Release Date:2023/01/12 16:46
-
Regarding model name of CC-Link cables
The CC‐Link cables are being produced by various manufacturers, and no specific cable model is recommended. Please use a cable certified by the CC-Link Asso... More Details >>
- No:22330
- Release Date:2018/08/30 13:55
- Update:2023/07/03 11:53
-
Regarding sending files in an SD Memory Card by Mail
Yes, as long as the capacity is expandable to the file register (R), it can be transmitted by using the file operation instruction. When sending, please set... More Details >>
- No:44369
- Release Date:2024/03/27 16:41
-
Regarding the MQTT communication function retransmission function
No, there is no function to resend all the data that could not be sent. By setting Retain and QoS from FB, it is possible to resend only the latest message. More Details >>
- No:44368
- Release Date:2024/03/27 16:56
-
Regarding FX5-ENET, FX5-ENET/IP IP addresses
You cannot configure two IP addresses. More Details >>
- No:44356
- Release Date:2024/03/27 15:56
-
Regarding the Number of Sending Addresses for Email function
The FX5-ENET module parameter of GX Works3 can send up to 10 messages and the module FB can send up to 256 characters at a time. By entering multiple email ... More Details >>
- No:40052
- Release Date:2023/08/25 10:23
-
Regarding the MQTT Communication Function Publish Program
You can't program it with the ladder program alone. To use the MQTT communication and email functions, you must use the module FB and program it. More Details >>
- No:40051
- Release Date:2023/08/25 11:48
-
Regarding FX5-CCLIEF Maximum Link Points
The maximum link points of the FX5-CCLIEF are 384 points each for RX/RY and 1024 points each for RWw/RWr. More Details >>
- No:40020
- Release Date:2023/08/24 14:31
-
Regarding the communication speed of FX5-CCLGN-MS
The FX5-CCLGN-MS firmware version 1.010 or later supports a communication speed setting of 100 Mbps. More Details >>
- No:39358
- Release Date:2023/01/12 17:09