Regarding CC-Link IE Field Network Station Type
Local stations can obtain information about all device stations. Intelligent device stations can only obtain information about their own stations. FX5-CCLI... More Details >>
- No:39301
- Release Date:2023/01/12 16:52
-
Regarding protocol creation of Predefined Protocol Support Function
You can not create a protocol for the other device. More Details >>
- No:39293
- Release Date:2023/02/13 15:38
-
Regarding error 2440H on CPU module when using FX5-CCLGN-MS
When the power is turned on, the FX5-CCLGN-MS performs parameter check processing, and if an error occurs, the CPU module is also notified of the error. Ther... More Details >>
- No:39282
- Release Date:2023/01/12 16:49
-
Regarding differences between instance communication and tag communication
Instance communication ・The instance ID (any number) is used to communicate with the other device. Tag communication ・The tag name (any character string) ... More Details >>
- No:45486
- Release Date:2025/11/12 13:55
-
Regarding checking the input/output data of the FX5-EIP
This can be checked by monitoring the corresponding buffer memory from the Register to Intelligent Function Module Monitor. From [Parameter] - [Module Infor... More Details >>
- No:45490
- Release Date:2025/05/08 09:08
- Update:2025/10/31 15:18
-
Regarding multiple connections for the MQTT communication function
The MQTT communication function of FX5-ENET does not allow multiple connections to be opened at the same time. The MQTT communication function has a maximum ... More Details >>
- No:44358
- Release Date:2024/03/27 16:02
-
Regarding setting up encrypted communication (TLS) for FX5-ENET
In GX Works3, set the FX5-ENET module parameters from Basic Settings - External Device Configuration Settings. In the "Ethernet Configuration" screen, selec... More Details >>
- No:40050
- Release Date:2023/08/25 08:48
-
Regarding simultaneous access to Web Server function
The Web server function allows you to log in from up to four devices at the same time. You can't log in from the fifth machine. More Details >>
- No:39330
- Release Date:2023/02/14 09:06
-
Regarding the connection between FX5-CCLGN-MS and NZ2GN2S-60AD4
Available. More Details >>
- No:39279
- Release Date:2023/01/12 16:47
-
Regarding support for the FX5-EIP Auto refresh function
The Auto refresh function is supported. More Details >>
- No:45488
- Release Date:2025/11/12 13:55