FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC iQ-F Series > Network/Communication
FAQ
Keyword Search
FAQ within [ Network/Communication ]
-
Regarding EtherNet/IP Communications
The built-in Ethernet port on the FX5 CPU module does not support EtherNet/IP communication. Use FX5-ENET/IP. More Details >>
- No:39319
- Release Date:2023/02/14 08:57
-
Regarding the communication execution status output device for ADPRW instructions
It does not turn OFF automatically. Use the RST command in the program to turn it OFF. More Details >>
- No:39349
- Release Date:2023/02/15 10:07
-
Regarding the supported version of the simple CPU communication function
For FX5U/FX5UC CPU module, firmware version 1.110 or later is supported. For the FX5UJ/FX5S CPU module, it is compatible from the first one. More Details >>
- No:39316
- Release Date:2023/02/14 08:56
-
Regarding the Connected/Disconnected Module Detection button on FX5-CCLGN-MS
For the Connected/Disconnected Module Detection of FX5-CCLGN-MS, the network configuration of the subsequent stages can not be automatically detected unless ... More Details >>
- No:39274
- Release Date:2023/01/12 16:45
-
Regarding PDO Mapping Settings
PDO mapping is configured from the CC-Link IE TSN configuration settings. ① Open the CC-Link IE TSN configuration settings from the FX5-CCLGN-MS Basic Set... More Details >>
- No:44475
- Release Date:2024/07/02 19:07
-
Regarding the MQTT communication function retransmission function
No, there is no function to resend all the data that could not be sent. By setting Retain and QoS from FB, it is possible to resend only the latest message. More Details >>
- No:44368
- Release Date:2024/03/27 16:56
-
Regarding MODBUS Device Allocation Settings
No need. The MODBUS device allocation settings are used when the MODBUS slave function is used. More Details >>
- No:40026
- Release Date:2023/08/24 14:37
-
Regarding error 2440H on CPU module when using FX5-CCLGN-MS
When the power is turned on, the FX5-CCLGN-MS performs parameter check processing, and if an error occurs, the CPU module is also notified of the error. Ther... More Details >>
- No:39282
- Release Date:2023/01/12 16:49
-
The FX5 CPU module does not support UDP broadcast communication. More Details >>
- No:22291
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:49
-
Regarding issuing Client Certificates to Connect with AWS IoT Core
Set the RSA strength to at least 2048 bits. Anything less than 2048 bits is not supported by AWS IoT Core and cannot be connected. More Details >>
- No:44343
- Release Date:2024/03/20 13:34
51-60 of Total 106