Regarding communication testing of Certificate Configuration Tool for FX5-ENET
The following are possible causes for communication not being established between the Certificate Configuration Tool for FX5-ENET and FX5-ENET. (1) Connecte... More Details >>
- No:40075
- Release Date:2023/08/25 09:06
-
Regarding the clean session function of MQTT communication function
This function allows you to select the operation to be performed when the FX5-ENET(MQTT client) reconnects to the MQTT broker after communication has been ... More Details >>
- No:40054
- Release Date:2023/08/25 09:02
-
Regarding the difference between the RS-485 expansion adapter and the extension board
The difference is the maximum transmission distance and the presence/absence of insulation (between the communication line and the CPU). ・Expansion Adapter ... More Details >>
- No:39315
- Release Date:2023/01/12 16:56
-
Regarding simultaneous access to Web Server function
The Web server function allows you to log in from up to four devices at the same time. You can't log in from the fifth machine. More Details >>
- No:39330
- Release Date:2023/02/14 09:06
-
Regarding FX5-ENET/IP parameter settings
You will need the EtherNet/IP Configuration Tool for FX5-ENET/IP. Download the tool from the FA site. More Details >>
- No:39302
- Release Date:2023/01/12 16:53
-
Regarding Open/Close Socket Communications
No need. More Details >>
- No:39288
- Release Date:2023/02/13 15:36
-
Regarding CC-Link IE TSN System Configuration with Mixed CC-Link IE TSN Class B/A Equipment
The boundary between the area of CC-Link IE TSN Class B equipment and the area of CC-Link IE TSN Class A equipment can use a general-purpose switching HUB an... More Details >>
- No:39283
- Release Date:2023/01/12 16:49
-
Regarding KeepAlive for SLMP Communication
For TCP protocol of SLMP communication, KeepAlive is fixed and cannot be changed. In the case of UDP protocol, it is fixed to not perform a keep-alive check. More Details >>
- No:45477
- Release Date:2025/11/12 13:37
-
Regarding Error code of FX5-ENET Mail send FB: H210
The following ranges overlap. Or the range of file register (R) used has been exceeded. Check whether the file register (R) is exceeded or not. ・area of de... More Details >>
- No:44608
- Release Date:2024/11/28 16:11
-
Regarding simultaneous execution of the MQTT communication function
The MQTT communication function cannot publish and subscribe at the same time. A program for the MQTT communication function is created using FB, but it c... More Details >>
- No:44345
- Release Date:2024/03/27 15:25