FAQ within [ Network/Communication ]
-
Regarding KeepAlive for SLMP Communication
For TCP protocol of SLMP communication, KeepAlive is fixed and cannot be changed. In the case of UDP protocol, it is fixed to not perform a keep-alive check. More Details >>
- No:45477
- Release Date:2025/11/12 13:37
-
Regarding CC-Link IE field network support of FX5 CPU module built-in Ethernet
The built-in Ethernet on the FX5 CPU module does not support CC-Link IE field networks. If you use a CC-Link IE field network, add an FX5-CCLIEF. *The FX5-... More Details >>
- No:44877
- Release Date:2025/03/18 10:30
-
Regarding Tag communication support of FX5-ENET/IP
Class1 communication of FX5-ENET/IP is instance communication. Tag communication is not supported. Tag communication is supported by FX5-EIP. More Details >>
- No:44624
- Release Date:2024/11/28 16:14
- Update:2025/11/11 14:32
-
Regarding multiple connections for the MQTT communication function
The MQTT communication function of FX5-ENET does not allow multiple connections to be opened at the same time. The MQTT communication function has a maximum ... More Details >>
- No:44358
- Release Date:2024/03/27 16:02
-
Regarding setting up encrypted communication (TLS) for FX5-ENET
In GX Works3, set the FX5-ENET module parameters from Basic Settings - External Device Configuration Settings. In the "Ethernet Configuration" screen, selec... More Details >>
- No:40050
- Release Date:2023/08/25 08:48
-
Using the email function of FX5-ENET, it is possible to send mail via a mail server. The email function is supported in the following versions. ・Hardware s... More Details >>
- No:40035
- Release Date:2023/08/24 15:40
- Update:2023/08/25 11:34
-
Regarding FX5-CCLIEF Maximum Link Points
The maximum link points of the FX5-CCLIEF are 384 points each for RX/RY and 1024 points each for RWw/RWr. More Details >>
- No:40020
- Release Date:2023/08/24 14:31
-
Regarding simultaneous access to Web Server function
The Web server function allows you to log in from up to four devices at the same time. You can't log in from the fifth machine. More Details >>
- No:39330
- Release Date:2023/02/14 09:06
-
Regarding the difference between the RS-485 expansion adapter and the extension board
The difference is the maximum transmission distance and the presence/absence of insulation (between the communication line and the CPU). ・Expansion Adapter ... More Details >>
- No:39315
- Release Date:2023/01/12 16:56
-
Regarding Error code of FX5-ENET Mail send FB: H210
The following ranges overlap. Or the range of file register (R) used has been exceeded. Check whether the file register (R) is exceeded or not. ・area of de... More Details >>
- No:44608
- Release Date:2024/11/28 16:11