Regarding remote I/O expansion for FX5S CPU module
It is possible to connect to remote I/O with CC-Link IE Field Network Basic. Up to 16 remote stations can be connected. More Details >>
- No:40041
- Release Date:2023/08/24 15:45
- Update:2025/03/13 10:08
-
CC-Link IE field When a network such as Network Basic is interrupted, the CPU module does not stop and continues to run. When the CC-Link IE Field Network i... More Details >>
- No:44611
- Release Date:2024/11/28 16:11
-
Regarding the login screen for the Web Server Function
There is no setting or method to disable the login screen for the web server function. More Details >>
- No:44357
- Release Date:2024/03/27 15:52
-
Regarding the communication execution status output device for ADPRW instructions
It does not turn OFF automatically. Use the RST command in the program to turn it OFF. More Details >>
- No:39349
- Release Date:2023/02/15 10:07
-
Regarding the connection configuration of FX5-CCL-MS
Connection is not allowed. For FX5-CCL-MS, only remote I/O stations, remote device stations andintelligent device stationscan be connected. More Details >>
- No:22316
- Release Date:2018/08/30 13:55
- Update:2023/07/03 17:19
-
Regarding communication supported by built-in RS-485 port
N:N Network, Parallel Link, MC protocol, Non-protocol communication, MELSOFT connection, MODBUS RTU, and Predefined protocol support are available. More Details >>
- No:22322
- Release Date:2018/08/30 13:55
- Update:2022/12/22 10:16
-
Regarding number of CC-Link IE field network Basic connections
When the FX5 CPU Module is used as the master station, the maximum number of devices connected to 1 network is 16. The following firmware versions are requi... More Details >>
- No:44652
- Release Date:2025/03/18 10:22
-
Regarding nesting contacts displayed on bus by master control instructions
It is not possible. More Details >>
- No:39361
- Release Date:2023/02/15 13:04
-
Regarding CC-Link IE field network support of FX5 CPU module built-in Ethernet
The built-in Ethernet on the FX5 CPU module does not support CC-Link IE field networks. If you use a CC-Link IE field network, add an FX5-CCLIEF. *The FX5-... More Details >>
- No:44877
- Release Date:2025/03/18 10:30
-
Regarding multiple connections for the MQTT communication function
The MQTT communication function of FX5-ENET does not allow multiple connections to be opened at the same time. The MQTT communication function has a maximum ... More Details >>
- No:44358
- Release Date:2024/03/27 16:02