FAQ
FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC iQ-F Series > Network/Communication
FAQ
Keyword Search
FAQ within [ Network/Communication ]
-
Regarding the type of Ethernet connection cable
Ethernet standard-compatible cable, category 5 or higher (STP cable) can be used. *Straight cable can be used. When connecting directly to the computer, cr... More Details >>
- No:22295
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:23
-
Regarding CC-Link settings using GX Works3
Parameters can be set when connecting the MELSEC iQ-F series with FX5-CCL-MS(CC-Link system master/intelligent device). However, when connecting with FX3U-1... More Details >>
- No:22317
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:19
-
Regarding expansion of communication ports
It is possible to use the MODBUS serial communication with multiple channels. However, only 1 channel can be set as the master. The MODBUS serial communica... More Details >>
- No:22323
- Release Date:2018/08/30 13:55
- Update:2023/06/26 09:04
-
Regarding model name of CC-Link cables
The CC‐Link cables are being produced by various manufacturers, and no specific cable model is recommended. Please use a cable certified by the CC-Link Asso... More Details >>
- No:22330
- Release Date:2018/08/30 13:55
- Update:2023/07/03 11:53
-
Regarding the connection between FX5-CCLGN-MS and inverter
FX5-CCLGN-MS supports 1 Gbps communication speed with firmware version: 1.010, and 1 Gbps and 100 Mbps communication speed for version 1.010. If the communi... More Details >>
- No:39281
- Release Date:2023/01/12 16:48
-
Regarding CC-Link IE TSN System Configuration with Mixed CC-Link IE TSN Class B/A Equipment
The boundary between the area of CC-Link IE TSN Class B equipment and the area of CC-Link IE TSN Class A equipment can use a general-purpose switching HUB an... More Details >>
- No:39283
- Release Date:2023/01/12 16:49
-
The FX5 CPU module does not support CAN communication. More Details >>
- No:39286
- Release Date:2023/02/13 15:36
-
Regarding Open/Close Socket Communications
No need. More Details >>
- No:39288
- Release Date:2023/02/13 15:36
-
Regarding the number of terminating resistors of FX5-CCL-MS
Two terminating resistors are included. More Details >>
- No:39290
- Release Date:2023/01/12 16:52
-
Regarding CC-Link IE Field Network Basic Communication Between FX5 CPU Modules
Since the FX5 CPU modules only support the master function, CC-Link IE Field Network Basic communication between FX5 CPU modules is not possible. More Details >>
- No:39297
- Release Date:2023/02/13 16:38