- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC iQ-F Series > Network/Communication
FAQ
Keyword Search
FAQ within [ Network/Communication ]
-
Regarding CC-Link IE field network support of FX5 CPU module built-in Ethernet
The built-in Ethernet on the FX5 CPU module does not support CC-Link IE field networks. If you use a CC-Link IE field network, add an FX5-CCLIEF. *The FX5-... More Details >>
- No:44877
- Release Date:2025/03/18 10:30
-
Regarding number of CC-Link IE field network Basic connections
When the FX5 CPU Module is used as the master station, the maximum number of devices connected to 1 network is 16. The following firmware versions are requi... More Details >>
- No:44652
- Release Date:2025/03/18 10:22
-
Regarding issuing Client Certificates to Connect with AWS IoT Core
Set the RSA strength to at least 2048 bits. Anything less than 2048 bits is not supported by AWS IoT Core and cannot be connected. More Details >>
- No:44343
- Release Date:2024/03/20 13:34
-
Regarding number of servo amplifiers that can be connected via PDO communication
The maximum number of servo amplifiers connected to the FX5-CCLGN-MS varies according to the number of axes. Example: When connecting a 3-axis servo amplifi... More Details >>
- No:44478
- Release Date:2024/07/02 19:07
-
Regarding Email function Attachments
The file formats and file sizes that can be attached by the email function are as follows: ・Attachments: Up to one file ・File formats: Binary, ASCII, CSV... More Details >>
- No:40057
- Release Date:2023/08/25 10:21
-
Regarding the connection between FX5-CCLGN-MS and SLMP-compatible devices
The SLMP communication frames supported by the FX5-CCLGN-MS are 3E and 4E frames. When SLMP communication is performed from an SLMP-compatible device to the... More Details >>
- No:39280
- Release Date:2023/01/12 16:48
-
Regarding the Connected/Disconnected Module Detection button on FX5-CCLGN-MS
For the Connected/Disconnected Module Detection of FX5-CCLGN-MS, the network configuration of the subsequent stages can not be automatically detected unless ... More Details >>
- No:39274
- Release Date:2023/01/12 16:45
-
Regarding the change of settings for reserved station (master station) of FX5-CCLGN-MS
FX5-CCLGN-MS allows the master station to change the reserved station setting with parameters, but the setting can not be changed by program. Note that link... More Details >>
- No:39275
- Release Date:2023/01/12 16:46
-
Regarding the connection between FX5-CCLGN-MS and NZ2GN2S-60AD4
Available. More Details >>
- No:39279
- Release Date:2023/01/12 16:47
-
Regarding maximum number of connections for MQTT communication function
The MQTT communication function can be used for up to one connection. More Details >>
- No:40055
- Release Date:2023/08/25 08:53