Regarding CC-Link IE Field Network Station Type
Local stations can obtain information about all device stations. Intelligent device stations can only obtain information about their own stations. FX5-CCLI... More Details >>
- No:39301
- Release Date:2023/01/12 16:52
-
Regarding issuing Client Certificates to Connect with AWS IoT Core
Set the RSA strength to at least 2048 bits. Anything less than 2048 bits is not supported by AWS IoT Core and cannot be connected. More Details >>
- No:44343
- Release Date:2024/03/20 13:34
-
Regarding connecting to AWS IoT Core Using the TCP Protocol
Because the AWS IoT Core specification is the TLS protocol, you cannot connect using the TCP protocol. More Details >>
- No:44344
- Release Date:2024/03/20 13:37
-
Regarding simultaneous execution of the MQTT communication function
The MQTT communication function cannot publish and subscribe at the same time. A program for the MQTT communication function is created using FB, but it c... More Details >>
- No:44345
- Release Date:2024/03/27 15:25
-
Regarding multiple connections for the MQTT communication function
The MQTT communication function of FX5-ENET does not allow multiple connections to be opened at the same time. The MQTT communication function has a maximum ... More Details >>
- No:44358
- Release Date:2024/03/27 16:02
-
Regarding CC-Link IE TSN CANopen Communication function
The CANopen communication functions supported by the FX5-CCLGN-MS conform to the CiA402 CANopen profile, and can control devices that support the CiA402 devi... More Details >>
- No:44474
- Release Date:2024/07/02 19:07
-
The batch setting of PDO mapping sets the default PDO mapping for all device stations that support PDO mapping. *Note that in the batch setting of PDO mappi... More Details >>
- No:44476
- Release Date:2024/07/02 19:06
-
Regarding number of servo amplifiers that can be connected via PDO communication
The maximum number of servo amplifiers connected to the FX5-CCLGN-MS varies according to the number of axes. Example: When connecting a 3-axis servo amplifi... More Details >>
- No:44478
- Release Date:2024/07/02 19:07
-
Regarding FX5-ENET/IP parameter settings
You will need the EtherNet/IP Configuration Tool for FX5-ENET/IP. Download the tool from the FA site. More Details >>
- No:39302
- Release Date:2023/01/12 16:53
-
Regarding QoS, Retain, Will, and Clean Session Functions for MQTT Communications
The QoS, Retain, Will, and Clean Session functions of the MQTT communication function can not be configured in buffer memory. Module FB: M+FX5ENET. QoS ca... More Details >>
- No:40053
- Release Date:2023/08/25 09:21