FAQ
FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC iQ-F Series > High-Speed Counter
FAQ
Keyword Search
FAQ within [ High-Speed Counter ]
-
Regarding cable diversion to FX5-2HC/ES
The cable cannot be used because the connector shape is different, so change the wiring. FX5-2HC/ES is a spring clamp terminal block, and FX3U-2HC is a MIL-... More Details >>
- No:44337
- Release Date:2024/03/20 13:26
-
Regarding the FX5-2HC/ES-enabled CPU module firmware version
The FX5-2HC/ES is supported by the following FX5 CPU Module firmware versions and GX Works3 versions: Firmware Version ・FX5U/FX5UC CPU Module: Ver. 1.300... More Details >>
- No:44341
- Release Date:2024/03/20 13:35
-
Regarding the differences between the FX5-2HC/ES and the conventional FX3U-2HC input formats
The FX5-2HC/ES supports differential line drivers (5 V) only. The FX3U-2HC supports open collectors (24 V/12 V/5 V) and differential line drivers (5 V). ... More Details >>
- No:44338
- Release Date:2024/03/26 09:02
-
Regarding FX5-2HC/ES restrictions
The FX5-2HC/ES must be connected to the eighth module from the power supply module (CPU Module, expansion power supply module, built-in power supply I/O Modu... More Details >>
- No:44339
- Release Date:2024/03/20 13:25
-
Regarding the maximum number of channels of high-speed counters
The FX5 CPU module's built-in high-speed counter can control up to 8CH. Up to 16CH can be controlled by adding 4 modules of FX5-16ET/E□-H (high-speed pulse ... More Details >>
- No:22311
- Release Date:2018/08/30 13:55
- Update:2023/02/13 15:34
-
Input filter adjustment when a high-speed counter or the interrupt function is used
When a coil of the high-speed counter or an interrupt pointer is programmed, the programmable controller system adjusts the filter constant of the correspond... More Details >>
- No:24867
- Release Date:2019/04/15 08:06
-
Regarding the driving contacts of high-speed counter instructions
The current value of the high-speed counter is retained and will not be cleared. More Details >>
- No:39304
- Release Date:2023/02/13 16:40
-
Regarding Input Response Frequency Difference between FX5-2HC/ES and Conventional Model (FX3U-2HC)
The input response frequencies of the FX5-2HC/ES and FX3U-2HC differ as shown below. FX5-2HC/ES・・・2MHz FX3U-2HC・・・200kHz More Details >>
- No:44340
- Release Date:2024/03/20 13:31
-
Regarding the number of available channels of the built-in high speeed counters.
The high-speed counter supports 1-phase 1-input, 1-phase 2-input, 2-phase 2-input. The built-in counter in the CPU module can input up to 8ch. However,... More Details >>
- No:22310
- Release Date:2018/08/30 13:55
- Update:2023/02/13 11:42
-
Regarding input of Differential Driver Output Type
It does not. The built-in high-speed counter of the FX5U/FX5UC CPU module does not support DC5V input. DC5V input can be achieved by adding BUS conversion mo... More Details >>
- No:39350
- Release Date:2023/01/12 17:09
1-10 of Total 13