1-7 of Total 7
Regarding the expansion of high-speed...
Up to 4 high-speed pulse input/output modules FX5-16ET/ES-H,FX5-16ET/ESS-H* can be expanded, allowing total of 16ch input (including built-in high speed coun... More Details >>
Regarding the frequency of high-speed...
The maximum frequency is 200kHz. (100kHz for 2 phast 2 input 2 edge mode, 50kHz for 4 edge mode ) More Details >>
Regarding input of Differential Drive...
It does not. The built-in high-speed counter of the FX5U/FX5UC CPU module does not support DC5V input. DC5V input can be achieved by adding BUS conversion mo... More Details >>
Regarding changing the current value ...
To rewrite the current value, arbitrary values can be written using the DHCMOV instruction. (Example) Set the current value of the high-speed counter ch1 to ... More Details >>
Input filter adjustment when a high-s...
When a coil of the high-speed counter or an interrupt pointer is programmed, the programmable controller system adjusts the filter constant of the correspond... More Details >>
Regarding the Certificate of non-appl...
For issuance of a certificate, please consult your local Mitsubishi representative. More Details >>
Regarding the maximum number of high-...
The high-speed counter supports 1-phase 1-input, 1-phase 2-input, 2-phase 2-input. The built-in counter in the CPU module can input up to 8ch. However, in t... More Details >>
1-7 of Total 7