Regarding analog ADP Power Supply abnormalities
H3081 is caused by an analog ADP power failure and the analog ADP is not receiving power normally. The FX5-4A-ADP and FX5-4DA-ADP are adapters that require p... More Details >>
- No:44346
- Release Date:2024/03/27 15:27
-
Regarding switching PID instructions for Auto-tuning
It's possible. More Details >>
- No:39320
- Release Date:2023/02/14 09:00
-
Regarding Control response parameter of built-in PID Control of CPU Module
The control response parameter can set the response to the target value (SV) of PID control as either "normal" or "fast". The difference is as follows. (1)W... More Details >>
- No:44653
- Release Date:2025/03/18 10:23
-
Regarding how to change the averaging processing of FX5-4AD-ADP programmatically
It is possible to change the number of counts for count averaging in a program. Set the module parameter Basic settings to "Set A/D conversion method" to Di... More Details >>
- No:44618
- Release Date:2024/11/28 16:13
-
Regarding the digital output of the built-in analog function
It is possible by setting the scaling function or shift function from the parameter settings. More Details >>
- No:22315
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:46
-
Regarding number of CH of CPU Module built-in Heating/Cooling PID control
The CPU Module's built-in Heating/Cooling PID control function supports up to 16 channels. The following firmware versions are required in order to use it. ... More Details >>
- No:44651
- Release Date:2025/03/18 10:22
-
Regarding the HOLD/CLEAR function of the built-in analog output
This function allows you to select the digital value to perform D/A conversion from the following three patterns depending on the operating status of the CPU... More Details >>
- No:39289
- Release Date:2023/01/12 16:51
-
Regarding the settings of built-in analog function of FX5U CPU module
The settings can be done using the parameter settings of GX Works3 or by settings the special relay/special registers. For further details please refer to M... More Details >>
- No:22314
- Release Date:2018/08/30 13:55
- Update:2023/06/26 09:20
-
Regarding the FX5UC CPU module/Intelligent Function module Power Cable
The model name of the power cable is FX2NC-100MPCB. It is included with the FX5UC CPU module and intelligent function modules that require power from the pow... More Details >>
- No:40021
- Release Date:2023/08/24 14:31
-
Regarding differences between Analog Module and Analog Adapters
FX5-4AD and FX5-4DA are intelligent function Modules. ・Connect to the right side of the CPU Module. ・Control via buffer memory (BFM). ・It also supports ... More Details >>
- No:44347
- Release Date:2024/03/27 15:21