FAQ


FAQAbout Products
- FAQ > Controllers > Motion Controllers > MELSEC-Q Series > Positioning Modules > QD75M
FAQ
Keyword Search
FAQ within [ QD75M ]
-
There are two ways to start a positioning operation: (1) Set the "[Cd.3] Positioning start No.", and turn ON the positioning start signal. (2) Use the dedica... More Details >>
- No:23593
- Release Date:2018/09/14 15:09
-
The following shows the initialization procedure. (1) Turn OFF the PLC ready flag. (2) Turn ON "[Cd.2] Parameter initialization request". [QD75M, QD75MH, LD... More Details >>
- No:23602
- Release Date:2018/09/14 15:09
-
Set "[Cd.16] Inching movement amount", and turn ON the Forward run JOG start signal or the Reverse run JOG start signal. More Details >>
- No:23590
- Release Date:2018/09/14 15:09
-
Error 2035 (Command frequency error) occurs when the servo amplifier detects a command frequency error. (1) When the command from the controller is the permi... More Details >>
- No:23616
- Release Date:2018/09/14 15:09
-
Error 1205 (SSCNET communication error) occurs when erroneous data is received from servo amplifier. [When the servo parameter "[PA14] Rotation direction se... More Details >>
- No:23614
- Release Date:2018/09/14 15:09
-
Refer to "b2: Command in-position flag" of "[Md.31] Status". More Details >>
- No:23598
- Release Date:2018/09/14 15:09
-
Check if 24 VDC power is supplied to "1A7" (pin No.) of the external input signal connector. More Details >>
- No:23594
- Release Date:2018/09/14 15:09
-
Torque is limited by the lower set value of "[Pr.17] Torque limit setting value" and "[Cd.22] New torque value".When the current torque reaches the limit, "b... More Details >>
- No:23592
- Release Date:2018/09/14 15:09
-
The torque limit value can be changed regardless of JOG operation status.Set the new torque limit value with "[Cd.22] New torque value". More Details >>
- No:23608
- Release Date:2018/09/14 15:09
21-29 of Total 29