FAQ within [ MELSEC iQ-R Series ]

1-10 of Total 45

prev 1 / 5page next
  • Setting the MELSEC iQ-R series inter-...

    Set modules in a module configuration diagram with GX Works3 and configure the inter-module synchronization setting. [Navigation Window]-> [Parameter]-... More Details >>

    • No:22492
    • Release Date:2018/09/03 17:28
    • Update:2018/09/20 10:01
  • How to use the database function of t...

    The database function manages tabular data including product information and production information as a database in a programmable controller. <... More Details >>

    • No:22476
    • Release Date:2018/09/03 17:28
    • Update:2018/09/19 14:44
  • Using a commercially-available SD mem...

    For the commercially-available SD memory cards that can be used for MELSEC iQ-R series CPU modules, refer to the following technical bulletin. - TECHNICAL ... More Details >>

    • No:22461
    • Release Date:2018/09/03 17:28
    • Update:2018/09/18 15:46
  • Combination of the MELSEC iQ-R series...

    You can use the MELSEC iQ-R series inter-module synchronization function together with the CC-Link IE Field Network synchronous communication function.With ... More Details >>

    • No:22462
    • Release Date:2018/09/03 17:28
    • Update:2018/09/18 15:51
  • The number of times to insert and rem...

    You can insert and remove the extended SRAM cassette less than 50 times and the SD memory card less than 500 times. More Details >>

    • No:22470
    • Release Date:2018/09/03 17:28
  • Using Q series terminal blocks and co...

    You can use a Q series 18-point screw terminal block with a MELSEC iQ-R series terminal block type I/O module or analog module. For a 40-pin connector type ... More Details >>

    • No:22474
    • Release Date:2018/09/03 17:28
    • Update:2018/09/19 14:37
  • Inter-module synchronization function...

    The inter-module synchronization function synchronizes the timing to control signals of multiple modules. This function synchronizes the input or output tim... More Details >>

    • No:22497
    • Release Date:2018/09/03 17:28
    • Update:2018/09/20 11:21
  • Parameters of GX Works3

    There are three types of parameters in GX Works3; "System parameter", "CPU parameter", and "Module parameter". You can set the following items with each par... More Details >>

    • No:22483
    • Release Date:2018/09/03 17:28
    • Update:2018/09/19 16:08
  • Database function of the MELSEC iQ-R ...

    You can manage tabular data including product information and production information as a database in a programmable controller. By accessing the database w... More Details >>

    • No:22477
    • Release Date:2018/09/03 17:28
    • Update:2018/09/19 14:53
  • IP filter function of MELSEC iQ-R ser...

    You can set IP addresses accessible to the CPU module and prevent unauthorized access to the CPU module. <Setting the IP filter function> [Navigati... More Details >>

    • No:22479
    • Release Date:2018/09/03 17:28
    • Update:2018/09/19 15:01

1-10 of Total 45