FAQ within [ MELSEC-Q Series ]
-
Whether or not device indirect specifications in structured ladder programs are allowed
Indirect specifications with "@" cannot be used in structured ladder programs and the Structured Text. Use indirect specifications in a ladder language program. More Details >>
- No:22697
- Release Date:2018/09/03 17:29
-
Specifying steps in printing data displayed in the window in GX Works2
GX Works2 Version 1.45X or later supports a print range specifying capability.Set "Start Step" and "End Step" for "Specified Print Range" in the Print window. More Details >>
- No:22695
- Release Date:2018/09/03 17:29
-
Runtime license for MX Component
A runtime license is required for all personal computers on which MX Component operates. More Details >>
- No:22657
- Release Date:2018/09/03 17:29
-
Cost of runtime licenses for VxWorks
The cost is included in the price of C Controller modules. Extra payment is not required. More Details >>
- No:22653
- Release Date:2018/09/03 17:29
-
It means that in an ambient temperature of 25 degrees Celsius, an error per day falls within the range of "delay of 2.57s" to "advance of 5.27s". "TYP.+2.22... More Details >>
- No:22651
- Release Date:2018/09/03 17:29
- Update:2018/09/26 16:53
-
The corresponding operation depends on the counter type selected. (1) If "Linear Counter" is selected If the present counter value exceeds the upper limi... More Details >>
- No:22624
- Release Date:2018/09/03 17:29
- Update:2018/09/21 10:32
-
The model name of Japanese version is SW[ ]D5C-SHEETSET-J and that of English version is SW[ ]D5C-SHEETSET-E. More Details >>
- No:22580
- Release Date:2018/09/03 17:29
-
Memory allocation for online change
The scan time may be substantially longer. Continue the operation if there is no problem with the longer scan time. More Details >>
- No:22575
- Release Date:2018/09/03 17:29
- Update:2018/09/20 17:01
-
Heat generation of Q61P power supply module
Since the conversion efficiency of the power supply module is approximately 70%, and 30% of the output power is dissipated as heat, the power consumption is ... More Details >>
- No:22529
- Release Date:2018/09/03 17:28
-
How to copy a sheet used by MX Sheet
Always change the name of the Excel sheet on which MX Sheet is set in the "Change Sheet Name" dialog box.If the sheet name is changed in the Excel sheet dire... More Details >>