Setting required to skip CC-Link slave station numbers
A CC-Link slave station number can be skipped by assigning the skipped number to a reserved station. A reserved station is counted as one of all the connecte... More Details >>
- No:23029
- Release Date:2018/09/03 17:31
-
CC-Link signals checked when an error occurs
Check the following signals.- Module error signal : X0- Host data link status signal: X1- Other station data link status signal: X3 More Details >>
- No:23021
- Release Date:2018/09/03 17:31
-
Settings required for transient transmission
The routing parameter settings are required for transient transmission to the CPU module with another network No. The request source station, relay station,... More Details >>
- No:22995
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:40
-
PLC parameter setting for QJ61BT11N
If the Network Parameter is used, CC-Link communication does not need the Select setting in the I/O assignment setting of the PLC parameter.If the parameter ... More Details >>
- No:23002
- Release Date:2018/09/03 17:31
-
Extending the station-to-station distance with a CC-Link IE controller
Use the optical media converter DMS-1000SL(-DC) (manufactured by Mitsubishi Electric System & Service Co., Ltd.). You can extend the station-to-station dista... More Details >>
- No:23067
- Release Date:2018/09/03 17:31
-
Limitation on the number of MELSOFT products that can be connected with the QJ71E71
In the TCP/IP connection, you can connect up to 17 MELSOFT products at the same time using a dedicated connection for system and the connections for users 1 ... More Details >>
- No:23063
- Release Date:2018/09/03 17:31
-
Continuous executions of protocols by the QJ71C24N series CPRTCL instruction
One CPRTCL instruction can execute a maximum of eight protocols. More Details >>
- No:23050
- Release Date:2018/09/03 17:31
-
SB/SW refresh device setting with CC-Link
There are no problems even though the SB/SW refresh device has not been set. More Details >>
- No:23080
- Release Date:2018/09/03 17:31
-
Cascade connections between hubs in the CC-Link IE Field Network
UP to 20 levels of cascade connections can be made. More Details >>
- No:23051
- Release Date:2018/09/03 17:31
- Update:2019/06/27 15:46
-
Model name of the connector used for the FCN connector type CC-Link remote I/O module
FCN connectors (40-pin connector) are shown below.- A6CON1 (soldering connector)- A6CON2 (crimp connector)- A6CON3 (pressure-displacement connector)- A6CON4 ... More Details >>
- No:23056
- Release Date:2018/09/03 17:31