  • Unit power consumption

    The module power consumption displays the power consumption of servo motor. Positive value indicates power running and negative value indicates regeneration. More Details >>

    • No:23636
    • Release Date:2018/09/14 15:10
  • Output check

    Using MR Configurator2, you can switch the output signals on/off forcibly independently of the servo status. This function is used for output signal wiring c... More Details >>

    • No:23639
    • Release Date:2018/09/14 15:10
  • Changing multiplication of analog torque command

    Yes, it is. For MR-J4-A/MR-J3-A, set by [Pr. PC13]. As the initial value (100.0%), the maximum torque is generated at ±8 V. To generate the maximum torque a... More Details >>

    • No:23628
    • Release Date:2018/09/14 15:10
  • Long distance wiring

    For the long wiring (50 m to 100 m) between the servo amplifier and servo motor, there are some precautions (encoder cable, etc.) to note. The wiring is not... More Details >>

    • No:23632
    • Release Date:2018/09/14 15:10
  • SSCNET III cable type

    Thickness of coating and length of cable provided More Details >>

    • No:23651
    • Release Date:2018/09/14 15:10
  • Wrong connection of servo amplifier power supply

    The system is probably malfunctioning and is in dangerous condition. Do not use it. For repair, contact your local sales office. More Details >>

    • No:23623
    • Release Date:2018/09/14 15:10
  • Encoder resolution during J3 compatibility mode

    18 bits (262,144 pulses/rev.) The encoder resolution of HG series servo motor in J4 mode is 22 bits (4,194,304 pulses/rev). For details of J3 compatibility m... More Details >>

    • No:23630
    • Release Date:2018/09/14 15:10
  • Positioning operation

    Using MR Configurator2, you can perform the positioning operation when there is no command from the controller. You can perform the operation specifying the ... More Details >>

    • No:23640
    • Release Date:2018/09/14 15:10
  • What are power running and regeneration?

    The power running is the status that the servo amplifier is supplying the power to the servo motor when the servo motor drives the load. (Example) When the s... More Details >>

    • No:23626
    • Release Date:2018/09/14 15:10
  • Motor-less operation

    The servo amplifier has the motor-less operation function. Without connecting the servo motor, output signals or status display can be provided in response t... More Details >>

    • No:23641