FAQ


FAQAbout Products

- FAQ > Low-voltage Power Distribution Products > Contactors and Motor Starters > Motor Starters
FAQ
Keyword Search
FAQ within [ Motor Starters ]
-
About Low-voltage Power Distribution Products
There is no surge suppressor for a control coil. The control coil of S-T65 toS-N800 type has the AC operation DC excitation method and includes thesurge supp... More Details >>
- No:23276
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
When a motor is overcurrent (overload) due to overload, constraint,phase-loss etc, a thermal load relay prevents motor burnout by heatingand bending a built-... More Details >>
- No:23269
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
RC stands for "Rated current" and the thermal load relay is usedaccording to the rated current (Full load current) of a motor. More Details >>
- No:23254
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
SD-T12 to T32 and SD-N600, N800 type operation coil terminals have polarity. Connect terminal mumber A1 (+) to the positive and A2 (-) to the negative sid... More Details >>
- No:23271
- Release Date:2018/09/12 15:11
- Update:2021/04/09 16:21
-
About Low-voltage Power Distribution Products
It is possible to open/close three-phase load by opening/closing two poleswith three-phase circuit. If US-H opens/closes two poles and theremaining pole is s... More Details >>
- No:23367
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
You must not desassemble it since mechanical latched type has beenadjusted and tested at our factory. More Details >>
- No:23325
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
Reverse connection is possible (connection of load side terminal as powerside and power side terminal as load side). However, it is necessary toinstall a mag... More Details >>
- No:23286
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
The faults of main circuit element in a solid state contactor happenbecause:1. Excessive overcurrent that is over permissible current flows due to loadcircui... More Details >>
- No:23258
- Release Date:2018/09/12 15:11
-
About Low-voltage Power Distribution Products
It is time from magnetizing or demagnetizing a control coil to operatingcontact (turning contact "ON" or "OFF"). More Details >>
- No:23343
- Release Date:2018/09/12 15:12
-
About Low-voltage Power Distribution Products
For US-N5/8SS(TE) and US-N70/80NS(TE), the rated impulse withstandvoltage is 4kV. For US-N20 to 50(TE) and US-NH70/NH80NS(TE), the ratedimpulse withstand vol... More Details >>
- No:23322
- Release Date:2018/09/12 15:11
- Update:2018/09/26 09:22
11-20 of Total 142