FAQ


FAQAbout Products
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Regarding maximum number of connections for the simple CPU communication function
The maximum number of connections for the simple CPU communication function of FX5 CPU module is 16 for FX5U/FX5UC CPU module and 8 for FX5UJ/FX5S CPU module... More Details >>
- No:40032
- Release Date:2023/08/24 15:37
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
By using the Time calculation FB library, you can perform calculations that across years, months and days. In the time calculation FB library, you can add an... More Details >>
- No:44362
- Release Date:2024/03/27 16:03
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
How to open GX Works2 projects in GX Developer
Select "Project" -> "Export to GX Developer Format File" from the menu of GX Works2 to save the project in the format that can be opened in GX Developer. More Details >>
- No:22514
- Release Date:2018/09/03 17:28
- Update:2018/09/20 13:40
- Category: MELSEC-Q Series
-
GX Works2 update installation procedure
Download the file directly under the C: drive and then install it. More Details >>
- No:22524
- Release Date:2018/09/03 17:28
- Update:2018/09/20 14:28
- Category: MELSEC-Q Series
-
The main units with Ver.3.10 or later can read and write programs of the FX3 series connected to the intelligent device station and can monitor devices. (GX ... More Details >>
- No:24990
- Release Date:2019/04/23 10:37
- Category: MELSEC-F Series , Main Unit , Network/Communication
-
The error code "2200" is "MISSING PARA.". The causes of the error are described below. (1) The necessary parameter file does not exist in all drives. (2) ... More Details >>
- No:22749
- Release Date:2018/09/03 17:29
- Update:2018/09/22 09:12
- Category: MELSEC-L Series
-
Latch (backup) areas in the data register (D) and extended register (R) of the FX3U/FX3UC series
D200 to D7999 and R0 to R32767 can be latched. D200 to D511 can be set as non-latch areas in parameters. For details on the parameter setting, refer to the... More Details >>
- No:24699
- Release Date:2019/02/27 08:58
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Regarding Boot Operation procedures
The boot operation function is configured and executed from the GX Works3 parameter settings as follows. (1) Open the boot configuration screen. From the... More Details >>
- No:44348
- Release Date:2024/03/27 15:29
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding the method to check the scan time
The current value of the scan time is stored in the following special devices. Please monitor using GX Works3. ◇Scan information SD520 Current scan time (... More Details >>
- No:22289
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:20
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding a mismatch found in the monitoring function of GX Works3
Perform "Rebuild All" and initialize the memory before writing to the PLC. "Rebuild All" converts the entire project and "Convert" only coverts the modified... More Details >>
- No:22293
- Release Date:2018/08/30 13:55
- Update:2023/02/13 15:31
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
1001-1010 of Total 1123