FAQ


FAQAbout Products

FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
MODE switch setting for QJ61BT11N
The MODE switch can set the following modes.- 0 to 4: Online mode- 5 to 9: Line test mode- A to E: Hardware test modeEach mode in ascending order of set valu... More Details >>
- No:23025
- Release Date:2018/09/03 17:31
- Category: Network related products
-
The CC-Link remote I/O modules' model names represents as follows:- AJ65SBTB1 - S: Compact type - B1: 1-wire terminal block, 1-common type- AJ65SBTB2 - S:... More Details >>
- No:22994
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Difference between CC-Link reserved stations and invalid stations
- Reserved station Reserved stations are not actually connected to the network (but will be connected in the future) but do not appear as data link error... More Details >>
- No:22993
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:37
- Category: Network related products
-
The number of CC-Link modules mountable with a universal model QCPU module
If the parameter is set, the following number of modules can be mounted at maximum. - Q00UJ/Q00U/Q01UCPU: Up to 2 modules - Q02UCPU: Up to 4 modules - Uni... More Details >>
- No:22981
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:20
- Category: Network related products
-
MX Component Version 4's compatibility with Visual C++ 6.0
MX Component Version 4 does not support Visual C++ 6.0. More Details >>
- No:22913
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
MX Component Version 4's compatibility with Visual Basic .NET 2003
MX Component Version 4 does not support Visual Basic .NET 2003. More Details >>
- No:22899
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Yes. As a guide, the processing time is shown below.For the logging condition, refer to figure 1 below. - For 16 devices: 2 ms - For 64 devices: 6 ms More Details >>
- No:22829
- Release Date:2018/09/03 17:30
- Update:2018/09/22 15:33
- Category: MELSEC-L Series
-
CPU operation when the time setting failed
When an error occurs, the operation can be stopped or continued according to the "At Error Occurrence" setting.(The default is "Continue".) More Details >>
- No:22828
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Restriction on the use of CPU when branch module and extension module are used
Use L series CPU modules whose first 5 digits of the serial number are "13072" or later. More Details >>
- No:22800
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Versions of built-in Ethernet port LCPU compatible with SNTP function
The initial version and subsequent versions of L series CPU support the SNTP function. More Details >>
- No:22769
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
1001-1010 of Total 1110