FAQ


FAQAbout Products
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Although it depends on interrupt factors, the overhead time before startup becomes 10.8 to 23.8 [us] and the time after startup becomes 6.5 to 17.4 [us]. More Details >>
- No:22499
- Release Date:2018/09/03 17:28
- Update:2018/09/20 12:14
- Category: MELSEC iQ-R Series
-
Regarding differences between instance communication and tag communication
Instance communication ・The instance ID (any number) is used to communicate with the other device. Tag communication ・The tag name (any character string) ... More Details >>
- No:45486
- Release Date:2025/11/12 13:55
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding Input Interrupt Delay
The following versions support the input interrupt delay function and can delay the start of execution. ・FX5U/FX5UC Ver. 1.290 or later ・FX5UJ Ver. 1.050 o... More Details >>
- No:40037
- Release Date:2023/08/24 15:43
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding FX5-CCLIEF Maximum Link Points
The maximum link points of the FX5-CCLIEF are 384 points each for RX/RY and 1024 points each for RWw/RWr. More Details >>
- No:40020
- Release Date:2023/08/24 14:31
- Category: MELSEC iQ-F Series , Network/Communication
-
Not supported. More Details >>
- No:39305
- Release Date:2023/02/13 16:41
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding CC-Link IE TSN System Configuration with Mixed CC-Link IE TSN Class B/A Equipment
The boundary between the area of CC-Link IE TSN Class B equipment and the area of CC-Link IE TSN Class A equipment can use a general-purpose switching HUB an... More Details >>
- No:39283
- Release Date:2023/01/12 16:49
- Category: MELSEC iQ-F Series , Network/Communication
-
You can set the parameters of the FL-net interface module with the data operation of the intelligent function module. For details and operation procedure of... More Details >>
- No:23084
- Release Date:2018/09/03 17:31
- Update:2018/09/26 13:19
- Category: Network related products
-
Unit of receive data used by the QJ71C24N series pre-defined protocol support function
The fixed data is used for specific codes and character strings such as a command. Setting a device is not required. More Details >>
- No:23049
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Connecting terminating resistors for CC-Link communication
Connect terminating resistors to both ends of physical cables.A master station is not necessarily required to be connected to either end of its network. More Details >>
- No:23046
- Release Date:2018/09/03 17:31
- Category: Network related products
-
CC-Link master modules' start I/O No. and refresh devices RX/RY
The I/O numbers used for I/O modules and intelligent function modules cannot be used as refresh targets for RX/RY. Use the I/O numbers greater than those use... More Details >>
- No:22997
- Release Date:2018/09/03 17:31
- Category: Network related products
1001-1010 of Total 1123