Controllers
FAQ within [ Controllers ]
-
The following shows the initialization procedure. (1) Turn OFF the PLC ready flag. (2) Turn ON "[Cd.2] Parameter initialization request". [QD75M, QD75MH, LD... More Details >>
-
It depends on the setting of servo parameter "[PA03] Absolute position detection system" whether the HPR request flag ("[Md.31] Status": b3) turns ON or not.... More Details >>
-
Set "[Cd.16] Inching movement amount", and turn ON the Forward run JOG start signal or the Reverse run JOG start signal. More Details >>
-
How to check the version of the MELSEC-F series
To check the version of the MELSEC-F series, connect GX Works2 (personal computer) or HPP to a programmable controller, and monitor the data in D8001. The l... More Details >>
- No:24772
- Release Date:2019/02/27 15:22
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Regarding the link refresh settings of FX5-CCL-MS
It is possible to use latch devices or I/O devices (X/Y) for link refresh devices. However, when using I/O devices (X/Y), use I/O numbers (such as X1000 ~/Y... More Details >>
- No:22308
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:37
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software , Network/Communication
-
Automatically assigned devices in GX Works2
Yes.Beginning with the device in the "Device/Label Automatic-Assign Setting" window, devices are assigned in descending order (from the greatest device numbe... More Details >>
- No:22846
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Both OUT and SET instructions set the device by completion of condition.However, if not completion of condition, OUT instruction resets the device while SET ... More Details >>
-
Yes. You can check the servo status through the following monitor data. • "[Md.108] Servo status 1" • "[Md.125] Servo status 3" (QD77MS, LD77MS, LD77MH) ... More Details >>
-
Regarding how to Monitor Buffer Memory Values
You can monitor buffer memory values in the Ladder Editor by setting in GX Works3 >Tools >Options > Monitor > Common Item > Monitor Buffer Mem... More Details >>
- No:39324
- Release Date:2023/01/12 16:56
- Category: MELSEC iQ-F Series , CPU Module
-
Acceleration/deceleration time change
Yes, the time can be changed during operation by using the acceleration/deceleration time change function. Set the acceleration/deceleration time change para... More Details >>
- No:23569
- Release Date:2018/09/14 15:09
- Category: RnMTCPU