Regarding analog ADP Power Supply abnormalities
H3081 is caused by an analog ADP power failure and the analog ADP is not receiving power normally. The FX5-4A-ADP and FX5-4DA-ADP are adapters that require p... More Details >>
- No:44346
- Release Date:2024/03/27 15:27
- Category: MELSEC iQ-F Series , Analog
-
I cannot select [Transfer Setup] in GX Developer because it is displayed in gray.
You cannot select the item while the programmable controller is being monitored. Execute [Close all windows] of [Window] from the tool bar, and check if Tra... More Details >>
- No:22955
- Release Date:2018/09/03 17:31
- Update:2018/09/25 12:11
- Category: Engineering Software
-
Displaying devices in GX Works2
Yes. The device use list also displays the devices used for specifying digits, such as "K4M0" (including M1, M2, or others). More Details >>
- No:22942
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
How to open GX Works2 projects in GX Developer
Select "Project" -> "Export to GX Developer Format File" from the menu of GX Works2 to save the project in the format that can be opened in GX Developer. More Details >>
- No:22514
- Release Date:2018/09/03 17:28
- Update:2018/09/20 13:40
- Category: MELSEC-Q Series
-
There are three types of parameters in GX Works3; "System parameter", "CPU parameter", and "Module parameter". You can set the following items with each par... More Details >>
- No:22483
- Release Date:2018/09/03 17:28
- Update:2018/09/19 16:08
- Category: MELSEC iQ-R Series
-
Compliance of the FX programmable controllers with the EU RoHS Directive
Most of the existing programmable controllers are compliant with the EU RoHS Directive. For details, please consult your local Mitsubishi Electric representa... More Details >>
- No:24888
- Release Date:2019/04/15 08:07
- Category: MELSEC-F Series , Main Unit , I/O Extension , Analog Control , High-Speed Counting , Positioning Control , Network/Communication , Accessories
-
Minor error 120 occurs in the following case:The zero pass signal (M2406+20n) is OFF when the re-movement to the home position is performed by proximity dog,... More Details >>
-
Check the following signals. • Start accept flag (M2001 to M2032) • Positioning start complete signal (M4000+20n (n: Axis No.-1)) More Details >>
-
Inputting device comments in GX Works2
Select [Tool] -> [Options] -> [Program Editor] -> "Ladder/SFC"-> "Comment" and change "Reference/Reflection Target for Device Comment" from "Glob... More Details >>
- No:22559
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Grounding FG and LG terminals of power supply module
Both of them need to be grounded. They can be shorted and grounded as one cable. More Details >>
- No:22527
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
121-130 of Total 1055