FAQ


FAQAbout Products
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Memory allocation for online change
The scan time may be substantially longer. Continue the operation if there is no problem with the longer scan time. More Details >>
- No:22575
- Release Date:2018/09/03 17:29
- Update:2018/09/20 17:01
- Category: MELSEC-Q Series
-
The setting in Latch (1) can be cleared by latch clear operation. The setting in Latch (2) cannot be cleared by latch clear operation. More Details >>
- No:22567
- Release Date:2018/09/03 17:29
- Update:2018/09/20 16:48
- Category: MELSEC-Q Series
-
Regarding Online program Change for FX5 CPU module
Ladder program, ST program ・It is supported from the first product. SFC program The following version supports Online program Change. ・FX5U/FX5UC module ... More Details >>
- No:40018
- Release Date:2023/08/24 14:30
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding clearing error with SM50
It is cleared by eliminating the cause of the error during detection and turning on SM50. For the error codes that can be cleared on the SM50, refer to the ... More Details >>
- No:39292
- Release Date:2023/02/13 15:37
- Category: MELSEC iQ-F Series , CPU Module
-
Input numbers of the FX programmable controllers
Since they are octal, the number after X7 is X10 and after X77 is X100. More Details >>
- No:25000
- Release Date:2019/04/23 10:39
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Model of the cable provided with the FX2N series extension unit
The model of the cable isFX0N-5EC. More Details >>
- No:24968
- Release Date:2019/04/23 07:19
- Category: MELSEC-F Series , Main Unit , I/O Extension
-
Number of occupied points of special function devices
Each special function unit/block has 8 occupied points, except for some special function devices. These 8 points do not occupy 8 points of the actual I/O n... More Details >>
- No:24873
- Release Date:2019/04/15 08:06
- Category: MELSEC-F Series , Main Unit
-
Data that can be stored in a memory cassette (FX3U/FX3UC)
The device memory data cannot be stored in a memory cassette. In the FX3U/FX3UC series, a part of device memory data can be latched using a battery. The de... More Details >>
- No:24789
- Release Date:2019/02/28 09:07
- Category: MELSEC-F Series , Accessories
-
Necessity of a battery when a memory cassette is used
A battery is not required when a memory cassette is used. This is because the sequence programsstored in the memory cassette, exceptfor RAM memory cassette, ... More Details >>
- No:24770
- Release Date:2019/02/27 15:00
- Category: MELSEC-F Series , Main Unit , Accessories
-
Torque is limited by the lower set value of "[Pr.17] Torque limit setting value" and "[Cd.22] New torque value".When the current torque reaches the limit, "b... More Details >>
- No:23592
- Release Date:2018/09/14 15:09
- Category: QD75M