The following points are different for the iQ-F series. ・Error History If the FX5 CPU Module is turned off, the error history is cleared. ・Setting detail... More Details >>
- No:44335
- Release Date:2024/03/20 13:21
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding automatic transfer of Data Logging Files
Data logging file transfer (FTP server auto transfer) is supported with the following firmware versions. ・FX5U/FX5UC CPU Module Ver. 1.300 or later ・FX5U... More Details >>
- No:44334
- Release Date:2024/03/20 13:30
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding forced ON/OFF function for external input/output
The "Forced ON/OFF function for external input/output" that forces X/Y devices to turn on/off from GX Works3 is supported with the following firmware version... More Details >>
- No:44330
- Release Date:2024/03/20 12:56
- Category: MELSEC iQ-F Series , CPU Module
-
Using the email function of FX5-ENET, it is possible to send mail via a mail server. The email function is supported in the following versions. ・Hardware s... More Details >>
- No:40035
- Release Date:2023/08/24 15:40
- Update:2023/08/25 11:34
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding the differences between Latches (1) and (2)
Whether the latch range is set by default is different. ・Latch (1) — Latch range is set by default. This can be changed at any time. ・Latch (2) — No latch ... More Details >>
- No:39351
- Release Date:2023/02/15 13:08
- Update:2024/08/19 09:54
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding GX Works3 Module configuration diagram
It can't be configured. In the module configuration diagram of GX Works3, the configurations that can be created are those excluding FX5-CNV-IFC and FX3 Int... More Details >>
- No:39331
- Release Date:2023/02/14 09:08
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding CC-Link IE Field Network Basic Refresh Settings
You can't. Device allocation for refresh settings is sequential only. More Details >>
- No:39306
- Release Date:2023/02/13 16:41
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Scan time while operation of a programmable controller CPU is being monitored using GX Works2
Scan time displayed on GX Works2 is the maximum scan time of the monitor target programmable controller CPU. To check current scan time, monitor the data in... More Details >>
- No:24779
- Release Date:2019/02/27 15:58
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Types of data backup methods (FX3G series)
1. Data backup using an optional battery Built-in RAM data and clock data of a programmable controller are held by using an optional battery. The life of... More Details >>
- No:24701
- Release Date:2019/02/27 08:59
- Category: MELSEC-F Series , Engineering Software , Main Unit , Accessories
-
Duplication error in a CC-Link master station
Possible causes are as follows.(1) Another master station exists on the same line.(2) Noise is detected on the line at power on. More Details >>
- No:23044
- Release Date:2018/09/03 17:31
- Category: Network related products