Data length for fixed buffer data communications by QJ71E71
The units of send data and receive data are shown below. - Fixed buffer data communications with the "Procedure Exist" control method: Words - Fixed buff... More Details >>
- No:23061
- Release Date:2018/09/03 17:31
- Update:2018/09/26 11:17
- Category: Network related products
-
Extending the station-to-station distance with a CC-Link IE controller
Use the optical media converter DMS-1000SL(-DC) (manufactured by Mitsubishi Electric System & Service Co., Ltd.). You can extend the station-to-station dista... More Details >>
- No:23067
- Release Date:2018/09/03 17:31
- Category: Network related products
-
SB/SW refresh device setting with CC-Link
SB/SW uses 512 points of refresh devices. More Details >>
- No:23081
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Assignment for connecting two CC-Link remote input modules (16-point type) (Remote net Ver.1 mode)
X devices will be assigned as follows. (With this setting, 32 points are occupied per station.) - Station No. 1: X100 to X11F -Station No. 2: X120 to X13... More Details >>
- No:23082
- Release Date:2018/09/03 17:31
- Update:2018/09/26 13:15
- Category: Network related products
-
Use a T-branch repeater module instead of a terminal block. More Details >>
- No:23086
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Output numbers of the FX programmable controllers
Since they are octal, the number after Y7 is Y10 and after Y77 is Y100. More Details >>
- No:24946
- Release Date:2019/04/18 14:26
- Category: MELSEC-F Series
-
Index modifier of the bit device in the FX3GC series
FX3GC series does not support the index modifier for the bit devices. FX3U/FX3UC series supports it. More Details >>
- No:25002
- Release Date:2019/04/23 10:39
- Category: MELSEC-F Series
-
Do not use vacant terminals. More Details >>
- No:25003
- Release Date:2019/04/23 10:39
- Category: MELSEC-F Series
-
When the block number of the file register (R) is saved and stored, the overhead time becomes 35.9 [us]. When the number of the file register is not saved o... More Details >>
- No:22465
- Release Date:2018/09/03 17:28
- Update:2018/09/19 11:57
- Category: MELSEC iQ-R Series
-
I/O numbers of a MELSEC iQ-R series I/O combined module (RH42C4NT2P)
An input and output use a single I/O number. (This is the same as QH42P.) When you replace a module that uses serial I/O numbers (e.g. QX41Y41P) with this m... More Details >>
- No:22471
- Release Date:2018/09/03 17:28
- Update:2018/09/19 13:57
- Category: MELSEC iQ-R Series