Minor error 197AH (Home position return zero not passed) occurs in the following case:"[St.1066] zero pass" is OFF when the re-movement to the home position ... More Details >>
- No:23560
- Release Date:2018/09/14 15:09
- Category: RnMTCPU
-
CC-Link slave station's flashing L.ERR LED
If the L.ERR LED flashes at irregular intervals, it may indicate that no terminating resistor has been connected or the communication is instable due to the ... More Details >>
- No:23001
- Release Date:2018/09/03 17:31
- Category: Network related products
-
How to copy a comment in GX Works2
1. Right-click the file name of a device comment to be copied, and select "Copy" from the menu.2. Right-click the file name of a device comment to which the ... More Details >>
- No:22939
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
MX Component Version 4's compatibility with Visual Basic .NET 2003
MX Component Version 4 does not support Visual Basic .NET 2003. More Details >>
- No:22899
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Limit on the display of data collected in GX LogViewer to 32 values
GX LogViewer is made to a specification that allows a single trend window to display a maximum of 32 graphs. When there are more than 32 logging data values,... More Details >>
- No:22889
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Memory allocation for online change in GX Developer
Select [Online] -> [Write to PLC] on the menu of GX Developer, open the [File selection] tab, and press "Param + Prog" button. Then open the [Program] ta... More Details >>
- No:22547
- Release Date:2018/09/03 17:28
- Update:2018/09/20 15:09
- Category: MELSEC-Q Series
-
Regarding changing the current value of the high-speed counter.
To rewrite the current value, arbitrary values can be written using the DHCMOV instruction. (Example) Set the current value of the high-speed counter ch1 ... More Details >>
- No:22303
- Release Date:2018/08/30 13:55
- Update:2023/02/06 17:05
- Category: MELSEC iQ-F Series , CPU Module , High-Speed Counter
-
From the [Module] tab ⇒ [Module FB] in the [Element Selection] window of GX Works3, drag and drop the Module FB you want to use to the program editor. More Details >>
- No:44606
- Release Date:2024/11/28 16:11
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding PDO Mapping Settings
PDO mapping is configured from the CC-Link IE TSN configuration settings. ① Open the CC-Link IE TSN configuration settings from the FX5-CCLGN-MS Basic Set... More Details >>
- No:44475
- Release Date:2024/07/02 19:07
- Category: MELSEC iQ-F Series , Network/Communication
-
Operation of the first special function unit/block in the FX3UC series
Usually, unit number of the first special function unit/block is "K0". However, when the main unit is FX3UC-32MT-LT(-LT2), the unit number "K0" is assigned t... More Details >>
- No:24995
- Release Date:2019/04/23 10:40
- Category: MELSEC-F Series , Main Unit