FAQ


FAQAbout Products
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Regarding number of expansion adapter connections
The number of expansion adapters varies depending on the type of adapter, and up to six can be connected. ・Analog adapter: Up to 4 ・Communication adapter: ... More Details >>
- No:44966
- Release Date:2025/05/08 09:05
- Category: MELSEC MX Controller MX-F Model
-
Regarding number of internal Ethernet port connections
The Ethernet port (P2) has 32 connections. The breakdown is as follows: total of MELSOFT connections, SLMP, and socket communications ≦ 32 connections. Apa... More Details >>
- No:44974
- Release Date:2025/05/08 09:07
- Category: MELSEC MX Controller MX-F Model
-
Software to be supplied with GX Works3
GX Works2 and GX Developer are supplied with GX Works3. When installing GX Works3, you can select whether to install GX Works2 and GX Developer together. More Details >>
- No:22463
- Release Date:2018/09/03 17:28
- Update:2018/09/18 16:14
- Category: MELSEC iQ-R Series
-
Make sure to turn off the power of the programmable controller before replacing the battery. Replacing the battery while the power of the programmable con... More Details >>
- No:22509
- Release Date:2018/09/03 17:28
- Update:2018/09/20 13:24
- Category: MELSEC-Q Series
-
Heat generation of Q61P power supply module
Since the conversion efficiency of the power supply module is approximately 70%, and 30% of the output power is dissipated as heat, the power consumption is ... More Details >>
- No:22529
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Boot operation from the standard ROM
The boot operation from the standard ROM is not possible.The program memory of universal model QCPU is a flash ROM.Thus, writing in the program memory achiev... More Details >>
- No:22553
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
The corresponding operation depends on the counter type selected. (1) If "Linear Counter" is selected If the present counter value exceeds the upper limi... More Details >>
- No:22624
- Release Date:2018/09/03 17:29
- Update:2018/09/21 10:32
- Category: MELSEC-Q Series
-
The numbers of POUs and steps of "Allocate Memory for 'Online Change'" in GX Works2
The maximum number of steps that an online change can process at a time is 512. More Details >>
- No:22672
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Input derating is the percentage of simultaneous ON points, one of the specifications applied when input modules are used. When QX42 is used in a temperatur... More Details >>
- No:22692
- Release Date:2018/09/03 17:29
- Update:2018/10/03 16:23
- Category: MELSEC-Q Series
-
Replacing an AnS I/O module with a Q I/O module
Yes. More Details >>
- No:22717
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
291-300 of Total 1110