Runtime license for MX Component
A runtime license is required for all personal computers on which MX Component operates. More Details >>
- No:22657
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Setting of Q series registers whose data is held when a power failure occurs
Assign data registers (D) to Latch (1) or Latch (2) in the "Device Setting" window ([PLC Parameter] -> "Device Setting" window) to hold the data when a po... More Details >>
- No:22601
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
No. More Details >>
- No:22589
- Release Date:2018/09/03 17:29
- Update:2018/09/20 17:42
- Category: MELSEC-Q Series
-
Periodic replacement is recommended. For example, standard life of FX3U-32BL is 5 years (at ambient temperature of 25). The life of the battery changes wit... More Details >>
- No:22262
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , Accessories
-
Regarding Statement and Note Types
PLC :it is written to the CPU module and consumes the number of steps. ・Without character - 3 steps ・With character : 4 + (Number of characters + 2 + 14) /... More Details >>
- No:40023
- Release Date:2023/08/24 15:39
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding differences between 8 bit and 16 bit modes for non-protocol communication
In 8-bit mode, the upper 8 bits of transmitted and received data are ignored and only the lower 8 bits are valid data. In 16 bit mode, send/receive data i... More Details >>
- No:39363
- Release Date:2023/02/15 13:04
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
CC-Link version of FX2N-16CCL-M
The CC-Link version ofFX2N-16CCL-M is Ver.1.10. More Details >>
- No:24992
- Release Date:2019/04/23 10:38
- Category: MELSEC-F Series , Network/Communication
-
Instruction execution complete flag
When a flag contact is not programmed directly under the instruction to be checked, the flag may be turned off depending on the execution status of another i... More Details >>
- No:24988
- Release Date:2019/04/23 07:22
- Category: MELSEC-F Series , Main Unit
-
Terminal layout on the output side of the FX3U-16MR/ES
Yes, they are independent common terminals. More Details >>
- No:24955
- Release Date:2019/04/18 14:23
- Category: MELSEC-F Series , Main Unit
-
The rapid stop deceleration time of parameter block is applied.However, when the rapid stop deceleration time is set in the servo program, the value is enabl... More Details >>