FAQ


FAQAbout Products
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Difference between L02CPU-P and L02CPU
In L02CPU-P, the general-purpose output of the built-in I/O is source type. In L02CPU, the general-purpose output of the built-in I/O is sink type. More Details >>
- No:22743
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Necessity for MX Component when MX Sheet is used
Yes.You can also purchase MX Works, a set of MX Sheet and MX Component. More Details >>
- No:22707
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
The Transfer Setup window is displayed in the Navigation window. More Details >>
- No:22579
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
How to read projects created by GX Works2 in GX Developer
Select [Project] -> [Export to GX Developer Format File] and save the project so that it can be opened in GX Developer.For more details, refer to GX Works... More Details >>
- No:22515
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Regarding dedicated instruction for JOG operation
There is no dedicated instruction to drive JOG. Use PLSV (variable speed operation) when operating JOG. More Details >>
- No:44355
- Release Date:2024/03/27 15:50
- Category: MELSEC iQ-F Series , CPU Module , Motion/Positioning
-
Regarding display of FX5-ENET/IP in a Module configuration Diagram
Please update GX Works3 to the latest version. After updating, FX5-ENET/IP is displayed in the Module configuration diagram of GX Works3. Download the lates... More Details >>
- No:39303
- Release Date:2023/01/12 17:13
- Category: MELSEC iQ-F Series , Engineering Software , Network/Communication
-
Regarding List Display/Edit Circuit Blocks
FX5 CPU module(GX Works 3) is not supported. More Details >>
- No:39291
- Release Date:2023/02/15 13:07
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Maximum length of input wiring
Although it depends on the operating environment, wiring within 20 m is generally recommended. More Details >>
- No:24949
- Release Date:2019/04/18 14:29
- Category: Main Unit
-
Time out error in the communication test of MX Component
The possible causes are as follows. - Incorrect setting with a personal computer or an Ethernet interface module Check the IP address, network number, sta... More Details >>
- No:22934
- Release Date:2018/09/03 17:30
- Update:2018/09/25 09:49
- Category: Engineering Software
-
Simultaneous use of simple PLC communication function and socket communication
The socket communication can be used simultaneously with the simple PLC communication function. More Details >>
- No:22740
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
461-470 of Total 1123