FAQ


FAQAbout Products

FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
KeepAlive setting for built-in Ethernet port in LCPU
The KeepAlive setting for the built-in Ethernet port in the L series is fixed. The setting is unchangeable. More Details >>
- No:22760
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
How to read the device memory in GX Works2
Select [Online] -> [Read from PLC] from the menu and check "Device Memory" in the file list in the window and then execute PLC read. More Details >>
- No:22621
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Unable to communicate via USB connection
Check the following points.(1) Transfer Setup is properly configured.(2) The USB driver is properly recognized. More Details >>
- No:22511
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
In the communication of the CC-Link IE Field Network synchronous communication function, you can synchronize the timing to send/receive data with the inter-... More Details >>
- No:22493
- Release Date:2018/09/03 17:28
- Update:2018/09/20 11:10
- Category: MELSEC iQ-R Series
-
Interrupt period setting of fixed scan interrupts of MELSEC iQ-R series
You can configure the setting in "Interrupt Setting from Internal Timer" of the CPU parameter. <Interrupt period setting> [Navigation Window]-> ... More Details >>
- No:22490
- Release Date:2018/09/03 17:28
- Update:2018/09/20 09:46
- Category: MELSEC iQ-R Series
-
The program cache memory (capacity) of the MX-F model is 12 MB. ※12 MB is equivalent to over 200K steps. More Details >>
- No:44990
- Release Date:2025/05/08 09:09
- Category: MELSEC MX Controller MX-F Model
-
Regarding connectable Intelligent Function modules
The MX-F Model can be connected to the intelligent function modules of the iQ-F series. Connectable intelligent function modules are shown below. More Details >>
- No:44983
- Release Date:2025/05/08 09:06
- Category: MELSEC MX Controller MX-F Model
-
Regarding Tag communication support of FX5-ENET/IP
Class1 communication of FX5-ENET/IP is instance communication. Tag communication is not supported. More Details >>
- No:44624
- Release Date:2024/11/28 16:14
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding analog ADP Power Supply abnormalities
H3081 is caused by an analog ADP power failure and the analog ADP is not receiving power normally. The FX5-4A-ADP and FX5-4DA-ADP are adapters that require p... More Details >>
- No:44346
- Release Date:2024/03/27 15:27
- Category: MELSEC iQ-F Series , Analog
-
Regarding editing device comments in the device usage list
Supported since GX Works3 Ver. 1.095Z, you can edit device comments from the device usage list. More Details >>
- No:40038
- Release Date:2023/08/24 15:44
- Category: MELSEC iQ-F Series , Engineering Software
461-470 of Total 1110