FAQ


FAQAbout Products

FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
The error code "2400" is "FILE SET ERROR". This error may be caused when the file specified with a parameter does not exist. The individual information param... More Details >>
- No:22729
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Storing the data logging setting to an SD memory card in LCPU
In the write logging setting, choose [Online] and [Write Logging Setting], and set the target memory to SD memory card. More Details >>
- No:22758
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Use of 4E frame for built-in Ethernet port of LCPU
The built-in Ethernet port in the L series is compatible only with the QnA-compatible 3E frame. The 4E frame is not supported. More Details >>
- No:22761
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
SNTP communication error in built-in Ethernet port LCPU
The error does not affect the CPU time. The CPU time is not set when a communication error occurs. More Details >>
- No:22783
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Compatibility between MX Component Version 3 and 4
Applications created using MX Component Version 3 can be used, as they are, on a personal computer on which MX Component Version 4 is installed. MX Component... More Details >>
- No:22839
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Languages supported by structured projects
Yes. More Details >>
- No:22855
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Statements of GX Works2 and the scan time
The input method for statements, either "PLC" or "Peripheral", makes a difference. - If "PLC" is set for statements, they are written into the program mem... More Details >>
- No:22856
- Release Date:2018/09/03 17:30
- Update:2018/09/22 14:18
- Category: Engineering Software
-
Using devices assigned as local labels in another program (GX Works2)
No.To read from another program, assign the devices as global labels. More Details >>
- No:22863
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Necessity of terminating resistors in CC-Link communication
No, it is unnecessary. Terminating resistors are only required at both ends of the network. More Details >>
- No:22966
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Terminating resistors for RS-485 communication of QJ71C24N
The resistance value is 110 ohm, 1/2 W. More Details >>
- No:22978
- Release Date:2018/09/03 17:31
- Update:2018/10/03 15:48
- Category: Network related products
471-480 of Total 1108