FAQ


FAQAbout Products
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Can I open a program created with GX Works2 in GX Developer?
You cannot open a program in the file format for GX Works2. When saving a project with GX Works2, save it in the format for GX Developer.(This is possible on... More Details >>
- No:22956
- Release Date:2018/09/03 17:31
- Category: Engineering Software
-
Remedies for WDT errors on a MELSECNET/H board
The error code indicates a WDT (watchdog timer) error. It is determined as the cause that the MELSECNET/H driver cannot work due to a computer or OS hang, or... More Details >>
- No:22969
- Release Date:2018/09/03 17:31
- Category: Network related products
-
CC-Link master modules' start I/O No. and refresh devices RX/RY
The I/O numbers used for I/O modules and intelligent function modules cannot be used as refresh targets for RX/RY. Use the I/O numbers greater than those use... More Details >>
- No:22997
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Model name of the connector used for the FCN connector type CC-Link remote I/O module
FCN connectors (40-pin connector) are shown below.- A6CON1 (soldering connector)- A6CON2 (crimp connector)- A6CON3 (pressure-displacement connector)- A6CON4 ... More Details >>
- No:23056
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Relation between CC-Link terminals and signal lines
The following shows the relations between CC-Link terminals and signal lines. - DA : Blue -DB: White -DG: Yellow More Details >>
- No:23077
- Release Date:2018/09/03 17:31
- Update:2018/09/26 13:11
- Category: Network related products
-
MELSOFT MT Works2 is engineering software for Motion controllers that provides comprehensive support - from system design, parameter settings, program creati... More Details >>
- No:23565
- Release Date:2018/09/14 15:09
- Category: MELSOFT MT Works2
-
Use of latched (battery backed) type auxiliary relay
If the OUT instruction using a latched (battery backed) type auxiliary relay number exists in a sequence program, the information held may be overwritten by ... More Details >>
- No:24877
- Release Date:2019/04/15 08:07
- Category: MELSEC-F Series , Main Unit
-
Terminal layout of the FX3U-1PG and FX2N-1PG pulse output blocks
Yes, they have the same terminal layout. More Details >>
- No:24900
- Release Date:2019/04/15 11:30
- Category: MELSEC-F Series , Positioning Control
-
Using the VPN (Virtual Private Network)*1 connection service enables the communications. VPN is a technology that connects networks by encrypting the commun... More Details >>
- No:24908
- Release Date:2019/04/15 11:32
- Category: MELSEC-F Series , Network/Communication
-
AnyWire-compatible master block of the FX programmable controller
The master block model is FX3U-128BTY-M. The FX3U-128BTY-M is compatible with the AnyWire Bitty series. More Details >>
- No:24923
- Release Date:2019/04/17 11:41
- Category: MELSEC-F Series , Network/Communication
491-500 of Total 1123