FAQ


FAQAbout Products
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Acceleration/deceleration time change
Yes, the time can be changed during operation by using the acceleration/deceleration time change function. Set the acceleration/deceleration time change para... More Details >>
-
Keyword protection of the MELSEC-F series
The keyword protection cannot be forcibly reset. Since only the keyword that has been registered by theuser is acceptable, please take measures to ensure th... More Details >>
- No:24784
- Release Date:2019/02/27 16:27
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
File registers "R" use the block switching method. The number of file register points used are divided and specified in units of 32k points. When multiple ... More Details >>
- No:22512
- Release Date:2018/09/03 17:28
- Update:2018/09/20 13:29
- Category: MELSEC-Q Series
-
How to copy comments from GX Developer to GX Works2
Launch GX Works2, select [Project] -> [Open Other Project], and read the data created with GX Developer. Copy the comment from the list of device comme... More Details >>
- No:22526
- Release Date:2018/09/03 17:28
- Update:2018/09/20 14:32
- Category: MELSEC-Q Series
-
Difference between QJ61BT11 and QJ61BT11N
QJ61BT11N supports Version 2 (expanded cyclic setting), the setting for refreshing/forced clearing a slave station data when the switch on a programmable con... More Details >>
- No:22964
- Release Date:2018/09/03 17:31
- Update:2018/09/25 13:16
- Category: Network related products
-
Maximum number of personal computers that can be communicated with the FX3U-ENET-L simultaneously
For communications using MELSOFT connection, such as GX Developer, GX Works2, GOT1000, and MX Component, up to two personal computers can be used. In additi... More Details >>
- No:24920
- Release Date:2019/04/17 11:41
- Category: MELSEC-F Series , Network/Communication
-
Temperature input modules that can be used with FX3G series
FX3U-4AD-PT-ADP (Pt100 temperature sensor input special adapter), FX3U-4AD-PTW-ADP (Pt100 temperature sensor input special adapter), and FX3U-4AD-TC-ADP (K/J... More Details >>
- No:24993
- Release Date:2019/04/23 10:38
- Category: MELSEC-F Series , Analog Control
-
Regarding how to check MAC Addresses
You can check the MAC address from the name plate on the side of the CPU module or by the Module diagnostics (CPU diagnostics) of GX Works3. More Details >>
- No:39294
- Release Date:2023/02/13 15:37
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Uninstalling GX Works2 before the installation of GX Works3
You do not have to uninstall GX Works2 before installing GX Works3. You can install GX Works3 into your computer where GX Works2 has already been installed. More Details >>
- No:22464
- Release Date:2018/09/03 17:28
- Update:2018/09/18 16:20
- Category: MELSEC iQ-R Series
-
GX Developer Version 8.89T or later is supported.There are restrictions in some functions. For the details, refer to "Precautions on L Series Modules" in ... More Details >>
- No:22792
- Release Date:2018/09/03 17:30
- Update:2018/10/03 16:26
- Category: MELSEC-L Series
501-510 of Total 1123