FAQ


FAQAbout Products

FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Regarding Circuit Blocks that cannot be written with Online Program Change.
HIOEN/DHIOEN instructions cannot be written with Online Program Change. In addition, circuit blocks containing positioning instructions or network instructio... More Details >>
- No:44354
- Release Date:2024/03/27 15:47
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding using the MQTT Communication function in a local environment
Yes, you can use MQTT communication function even in the local network by preparing a personal computer with MQTT broker such as Eclipse Mosquitto installed.... More Details >>
- No:44367
- Release Date:2024/03/27 16:46
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding Error code of FX5-ENET Mail send FB: H210
The following ranges overlap. Or the range of file register (R) used has been exceeded. Check whether the file register (R) is exceeded or not. ・area of de... More Details >>
- No:44608
- Release Date:2024/11/28 16:11
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding number of occupied I/O points of intelligent function module
The number of occupied input/output points per module is 8. (Excluding some models) Occupied I/O points: Since actual occupied I/O points cannot be assigned... More Details >>
- No:44612
- Release Date:2024/11/28 16:12
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding how to change the averaging processing of FX5-4AD-ADP programmatically
It is possible to change the number of counts for count averaging in a program. Set the module parameter Basic settings to "Set A/D conversion method" to Di... More Details >>
- No:44618
- Release Date:2024/11/28 16:13
- Category: MELSEC iQ-F Series , Analog
-
Regarding Tag communication support of FX5-ENET/IP
Class1 communication of FX5-ENET/IP is instance communication. Tag communication is not supported. More Details >>
- No:44624
- Release Date:2024/11/28 16:14
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding Recommended Substitute Models for FX3G-CNV-ADP
The FX5 CPU modules allows you to add an expansion adapter without using a connector conversion adapter. Therefore, there is no Recommended Substitute Models... More Details >>
- No:44875
- Release Date:2025/03/18 10:27
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding the controller Line-up
The MX-F Model has the following features. More Details >>
- No:44964
- Release Date:2025/05/08 09:06
- Category: MELSEC MX Controller MX-F Model
-
Regarding the range of latch devices
The latch range can be set arbitrarily by the customer. The settings can be found in the memory/device settings of CPU parameters. To back up the link regist... More Details >>
- No:22297
- Release Date:2018/08/30 13:55
- Category: MELSEC iQ-F Series , CPU Module
-
Security key authentication function of MELSEC iQ-R series
The security key authentication function registers a security key in a program file and prevents unauthorized execution or access to the program.You can set... More Details >>
- No:22480
- Release Date:2018/09/03 17:28
- Update:2018/09/19 15:38
- Category: MELSEC iQ-R Series
581-590 of Total 1108