Controllers
FAQ within [ Controllers ]
-
Read and write operations for CC-Link buffer memory
There is no problem in writing/reading data into/from the buffer memory using a FROM/TO instruction with the refresh device setting left blank.The refresh de... More Details >>
- No:23015
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Using a FROM/TO instruction after AJ71UC24 is replaced with QJ71C24N
I/O signals and buffer memory addresses need to be changed but data communications can be conducted using a FROM/TO instruction and X/Y signals. More Details >>
- No:23017
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Connecting AJ65BT-R2N to a GOT
Yes.When connecting a GOT, set the mode setting switch of AJ65BT-R2N to "5" (MELSOFT connection mode). More Details >>
- No:23047
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Precaution about MELSECNET/H connection (1)
- Set successive station numbers for the network modules in system A and system B in a redundant system. (Station number 0 cannot be set.) - Match "host... More Details >>
- No:23055
- Release Date:2018/09/03 17:31
- Update:2018/09/26 11:12
- Category: Network related products
-
Output numbers of the FX programmable controllers
Since they are octal, the number after Y7 is Y10 and after Y77 is Y100. More Details >>
- No:24946
- Release Date:2019/04/18 14:26
- Category: MELSEC-F Series
-
Regarding the expansion of modules after the bus conversion module
It is not possible to add an iQ-F series module after the bus conversion module. When adding an iQ-F series module, add it in the front stage of the bus conv... More Details >>
- No:45482
- Release Date:2025/11/12 13:55
- Category: MELSEC iQ-F Series , CPU Module
-
Models of batteries that can be used with MELSEC iQ-R series CPU modules
You can use "Q6BAT" and "Q7BAT". You cannot use "Q8BAT". More Details >>
- No:22469
- Release Date:2018/09/03 17:28
- Category: MELSEC iQ-R Series
-
In the communication of the CC-Link IE Field Network synchronous communication function, you can synchronize the timing to send/receive data with the inter-... More Details >>
- No:22493
- Release Date:2018/09/03 17:28
- Update:2018/09/20 11:10
- Category: MELSEC iQ-R Series
-
Use SP.FWRITE instruction to save the data to an ATA card in CSV format.For Q00UJCPU, Q00UCPU, and Q01UCPU, however, memory cards cannot be used thus data ca... More Details >>
- No:22652
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
SD memory cards used for Q24DHCCPU-V
Mitsubishi Electric's SD memory cards, which can be installed into Q24DHCCPU-V, are shown below. - NZ1MEM-2GBSD (memory capacity: 2Gbytes) - NZ1MEM-4GBSD (... More Details >>
- No:22711
- Release Date:2018/09/03 17:29
- Update:2018/09/22 08:58
- Category: MELSEC-Q Series