Mixing the CC-Link IE Field Network with general LAN communication
Mixed communication with the same hub cannot be established. Establish the CC-Link IE Field Network and general LAN communication separately. More Details >>
- No:22988
- Release Date:2018/09/03 17:31
- Update:2019/06/27 15:48
- Category: Network related products
-
NTP support by the SNTP function of LCPU with built-in Ethernet port
NTP and SNTP are compatible. Therefore, an NTP server can be used for clock setting. More Details >>
- No:22744
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Number of FX3U-1PG pulse output blocks that can be connected to the FX3U/FX3UC main unit
For the FX3U series, up to eight FX3U-1PGs can be connected. For the FX3UC series, up to six FX3U-1PGs can be connected. * To connect the FX3U-1PG to the... More Details >>
- No:24973
- Release Date:2019/04/23 07:19
- Category: MELSEC-F Series , Positioning Control
-
It takes 1 ms or less in a unit of the motor system and 2 ms or less in a unit of the machine system. * Motor system∙∙∙The pulse number is used as the stand... More Details >>
- No:24943
- Release Date:2019/04/18 14:25
- Category: MELSEC-F Series , Positioning Control
-
Memory allocation for online change
The scan time may be substantially longer. Continue the operation if there is no problem with the longer scan time. More Details >>
- No:22575
- Release Date:2018/09/03 17:29
- Update:2018/09/20 17:01
- Category: MELSEC-Q Series
-
PLC type change in GX Developer
Follow the steps below and then execute PLC type change.- On the menu of GX Developer, select [Online] -> [Monitor] -> [Stop Monitoring (All Windows)],... More Details >>
- No:22522
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Memory allocation for online change in GX Works2
The capacity of parameters and programs subtracted from the program capacity for the CPU type in use equals the size of the maximum number of steps. More Details >>
- No:22671
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
I/O assignment of PLC parameters with GX Works3
"PC Parameter" in GX Works2 is "Parameter" in GX Works3. You can set the I/O assignment from "Module Configuration" or "System Parameter". <Setting fr... More Details >>
- No:22475
- Release Date:2018/09/03 17:28
- Update:2018/09/19 14:42
- Category: MELSEC iQ-R Series
-
Changing the time of a programmable controller by using the clock data write instruction (TWR)
When changing the time by using the clock data write instruction (TWR), the control of M8015 (Clock stop/adjustment) is not required. * When the clock data... More Details >>
- No:22266
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Regarding a mismatch found in the monitoring function of GX Works3
Perform "Rebuild All" and initialize the memory before writing to the PLC. "Rebuild All" converts the entire project and "Convert" only coverts the modified... More Details >>
- No:22293
- Release Date:2018/08/30 13:55
- Update:2023/02/13 15:31
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software