FAQ


FAQAbout Products
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Regarding how to start positioning
In the case of positioning control and OPR control, there are three ways to start positioning: (1)[cd. 184] Turn on the positioning start signal. (2)Exec... More Details >>
- No:39360
- Release Date:2023/01/12 17:19
- Category: MELSEC iQ-F Series , Motion/Positioning
-
Regarding write speed during RUN
CC-Link IE field Network Basic communication interval can be set with special relay and special register. During debugging, adjust the communication interv... More Details >>
- No:44342
- Release Date:2024/03/20 13:39
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding configuring of Data Logging
The CPU module logging feature is accessed from the CPU module logging configuration tool. If the tool is installed, launch it from GX Works3 Tools > Logg... More Details >>
- No:44613
- Release Date:2024/11/28 16:12
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
From the following menu of GX Works3: [Diagnostics]→[Module Diagnostics(CPU Diagnostics)] the event history function can be found. The event history can dis... More Details >>
- No:22305
- Release Date:2018/08/30 13:55
- Update:2023/02/13 11:37
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Database function of the MELSEC iQ-R series
You can manage tabular data including product information and production information as a database in a programmable controller. By accessing the database w... More Details >>
- No:22477
- Release Date:2018/09/03 17:28
- Update:2018/09/19 14:53
- Category: MELSEC iQ-R Series
-
How to use file registers R in the Q series
File registers R can be used for data whose size is exceeding 32k points with RSET instruction, which is a block switching instruction. Use file registers... More Details >>
- No:22525
- Release Date:2018/09/03 17:28
- Update:2018/09/20 14:29
- Category: MELSEC-Q Series
-
The error code "2110" is "SP.UNIT ERROR.". This error may be caused by one of the following factors. (1) The module that has been specified by a FROM/TO i... More Details >>
- No:22662
- Release Date:2018/09/03 17:29
- Update:2018/09/21 13:48
- Category: MELSEC-Q Series
-
Execution of the SOCRMODE instruction in the same connection during socket communication of LCPU
It can be executed for the same connection number. When data exist in the socket communication receive data area and the SOCRMODE instruction is executed, va... More Details >>
- No:22771
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
SD1284 of LCPU with built-in Ethernet port
The bits 0 to F of the special register SD1284 (Open request signal) correspond to the connection numbers 1 to 16. When the open request is sent, the corresp... More Details >>
- No:22784
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Switch settings of intelligent function module and I/O assignment settings (GX Works2)
Those switch settings are connected with each other. The switch setting of intelligent function module settings are easier to set. More Details >>
- No:22883
- Release Date:2018/09/03 17:30
- Category: Engineering Software
681-690 of Total 1123