Regarding the built-in positioning function
The MX-F Model also supports the built-in positioning function. The number of control axes is now 4, and PULSE/SIGN and CW/CCW are supported. The maximum f... More Details >>
- No:44978
- Release Date:2025/05/08 09:08
- Category: MELSEC MX Controller MX-F Model
-
Regarding sending files in an SD Memory Card by Mail
Yes, as long as the capacity is expandable to the file register (R), it can be transmitted by using the file operation instruction. When sending, please set... More Details >>
- No:44369
- Release Date:2024/03/27 16:41
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding analog ADP Power Supply abnormalities
H3081 is caused by an analog ADP power failure and the analog ADP is not receiving power normally. The FX5-4A-ADP and FX5-4DA-ADP are adapters that require p... More Details >>
- No:44346
- Release Date:2024/03/27 15:27
- Category: MELSEC iQ-F Series , Analog
-
Regarding how to start positioning
In the case of positioning control and OPR control, there are three ways to start positioning: (1)[cd. 184] Turn on the positioning start signal. (2)Exec... More Details >>
- No:39360
- Release Date:2023/01/12 17:19
- Category: MELSEC iQ-F Series , Motion/Positioning
-
Regarding CC-Link IE Field Network Basic Refresh Settings
You can't. Device allocation for refresh settings is sequential only. More Details >>
- No:39306
- Release Date:2023/02/13 16:41
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
CC-Link signals checked when an error occurs
Check the following signals.- Module error signal : X0- Host data link status signal: X1- Other station data link status signal: X3 More Details >>
- No:23021
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Settings required for transient transmission
The routing parameter settings are required for transient transmission to the CPU module with another network No. The request source station, relay station,... More Details >>
- No:22995
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:40
- Category: Network related products
-
Difference between AJ65SBTB1-32DT and AJ65SBTB1-32DT2
Major differences are shown below. - AJ65SBTB1-32DT- Leakage current at OFF 0.25 mA or lower- Protection function (overload protection, overvoltage protectio... More Details >>
- No:22985
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Function blocks and PLC type change
Yes. Execute conversion/compilation after changing the PLC type. More Details >>
- No:22931
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Index modification when using extended data register in LCPU
It is not possible to specify index modification to cross over the boundary between the internal user device (D) and the extended data register (D). Change t... More Details >>
- No:22822
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
731-740 of Total 1123