The following shows the initialization procedure. (1) Turn OFF the PLC ready flag. (2) Turn ON "[Cd.2] Parameter initialization request". [QD75M, QD75MH, LD... More Details >>
-
The BUSY signal turns ON even when position control of movement amount "0" is executed.However, since the ON time is short, the ON status may not be detected... More Details >>
-
Comparison result of the CMP instruction
A comparison result is held even after the command input turns off. The remaining comparison result can be cleared by using the RST or ZRST instruction. More Details >>
- No:24692
- Release Date:2019/02/27 08:56
- Category: MELSEC-F Series
-
Cable provided with the FX2N series extension unit
It is available as a repair part. Please consult with localMitsubishi Electric representative. More Details >>
- No:24916
- Release Date:2019/04/17 11:40
- Category: MELSEC-F Series , Main Unit , I/O Extension
-
Ver.3.10 or later is applicable. (GX Works2 with Ver.1.73B or later is applicable.) The version of the main unit can be checked with the last three digits of... More Details >>
- No:24918
- Release Date:2019/04/17 11:40
- Category: MELSEC-F Series , Main Unit
-
The station number setting is not required for non-protocol communication. More Details >>
- No:24948
- Release Date:2019/04/18 14:27
- Category: MELSEC-F Series , Main Unit , Network/Communication
-
Target address change during the positioning operation in the FX3U-1PG
Yes, it is possible. Set a new value for the target address to the target address change value (BFM#54, #53) during the positioning operation. * The targ... More Details >>
- No:24986
- Release Date:2019/04/23 07:22
- Category: MELSEC-F Series , Positioning Control
-
Regarding EtherNet/IP Communications
The built-in Ethernet port on the FX5 CPU module does not support EtherNet/IP communication. Use FX5-ENET/IP. More Details >>
- No:39319
- Release Date:2023/02/14 08:57
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding converting FBD/LD Projects
It can't be converted. More Details >>
- No:39328
- Release Date:2023/02/14 09:05
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding how to start positioning
In the case of positioning control and OPR control, there are three ways to start positioning: (1)[cd. 184] Turn on the positioning start signal. (2)Exec... More Details >>
- No:39360
- Release Date:2023/01/12 17:19
- Category: MELSEC iQ-F Series , Motion/Positioning