Controllers
FAQ within [ Controllers ]
-
Regarding how to Monitor Buffer Memory Values
You can monitor buffer memory values in the Ladder Editor by setting in GX Works3 >Tools >Options > Monitor > Common Item > Monitor Buffer Mem... More Details >>
- No:39324
- Release Date:2023/01/12 16:56
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding EtherCAT Communications
The FX5 CPU module does not support EtherCAT communication. There are no products in the FX series or iQ-F series that support EtherCAT communication. More Details >>
- No:39313
- Release Date:2023/02/14 08:54
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Check if 24 VDC power is supplied to "1A7" (pin No.) of the external input signal connector. More Details >>
-
Alarm 2149 (Main circuit OFF warning) occurs when the servo system turns ON with no power supplied to the servo main circuit. Review the condition of servo O... More Details >>
-
How to install a USB driver in Windows XP
For how to install a USB driver in Windows XP, refer to the following procedure. (1) Connect a personal computer and a programmable controller CPU with a ... More Details >>
- No:22933
- Release Date:2018/09/03 17:30
- Update:2018/09/22 16:59
- Category: Engineering Software
-
Latch (backup) areas in the data register (D) and extended register (R) of the FX3U/FX3UC series
D200 to D7999 and R0 to R32767 can be latched. D200 to D511 can be set as non-latch areas in parameters. For details on the parameter setting, refer to the... More Details >>
- No:24699
- Release Date:2019/02/27 08:58
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Regarding the link refresh settings of FX5-CCL-MS
It is possible to use latch devices or I/O devices (X/Y) for link refresh devices. However, when using I/O devices (X/Y), use I/O numbers (such as X1000 ~/Y... More Details >>
- No:22308
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:37
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software , Network/Communication
-
I/O assignment of PLC parameters with GX Works3
"PC Parameter" in GX Works2 is "Parameter" in GX Works3. You can set the I/O assignment from "Module Configuration" or "System Parameter". <Setting fr... More Details >>
- No:22475
- Release Date:2018/09/03 17:28
- Update:2018/09/19 14:42
- Category: MELSEC iQ-R Series
-
Regarding registering profiles
Launch GX Works3, select a profile and register it from Tools > Profile Management > Register. More Details >>
- No:44360
- Release Date:2024/03/27 16:01
- Category: MELSEC iQ-F Series , Engineering Software
-
How to check devices assigned to labels of GX Works3
GX Works3 and the MELSEC iQ-R series do not use actual devices as automatic assignment devices of local labels. The local labels use "label areas" in the "d... More Details >>
- No:22486
- Release Date:2018/09/03 17:28
- Update:2018/09/20 09:30
- Category: MELSEC iQ-R Series
81-90 of Total 1110