Regarding GX Works3 Module configuration diagram
It can't be configured. In the module configuration diagram of GX Works3, the configurations that can be created are those excluding FX5-CNV-IFC and FX3 Int... More Details >>
- No:39331
- Release Date:2023/02/14 09:08
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Periodic replacement is recommended. For example, standard life of FX3U-32BL is 5 years (at ambient temperature of 25). The life of the battery changes wit... More Details >>
- No:22262
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , Accessories
-
It depends on the model of the CPU module, the amount of battery consumption, and the power-on time ratio.Example) For Q06HCPU with power-on time ratio of 50... More Details >>
- No:22523
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Local devices are devices which can be independently used for each program.When multiple independent programs are executed, using local devices allows progra... More Details >>
- No:22531
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
GX Simulator in GX Works2 disk
The simulation function is included in GX Works2.For more details of the functions of GX Work2, refer to GX Works2 Version 1 Operating Manual (Common). More Details >>
- No:22537
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
The cross reference window is not displayed.
Select [View]-> [Cross reference window] from the menu in GX Developer to display the cross reference window. More Details >>
- No:22951
- Release Date:2018/09/03 17:30
- Update:2018/09/25 11:54
- Category: Engineering Software
-
Set "[PA04] Function selection A-1" to "_1_ _h: Invalid".(Note): When using Q17nCPUN, set "Servo amplifier parameter 23 (Optional function 1)"... More Details >>
-
The Transfer Setup window is displayed in the Navigation window. More Details >>
- No:22579
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Making transparent connections using GX Developer
Set as follows in the Transfer Setup window. - Select "USB" for "PC side I/F". - Select "CPU Module" for "PLC side I/F" and check "via GOT (direct couple... More Details >>
- No:22640
- Release Date:2018/09/03 17:29
- Update:2018/09/21 11:39
- Category: MELSEC-Q Series
-
How to check errors with error codes of QD75
Errors can be checked with the following error detection signals and buffer memory areas corresponding to each axis.- Axis 1 Error detection X8 Buffer memor... More Details >>
- No:22667
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series