How to display local comments in GX Works2
In the "Reference/Reflection Target for Device Comment" window, switch the "Specify the Reference/Reflection" from "Global" to "Local". More Details >>
- No:22630
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Regarding EtherCAT Communications
The FX5 CPU module does not support EtherCAT communication. There are no products in the FX series or iQ-F series that support EtherCAT communication. More Details >>
- No:39313
- Release Date:2023/02/14 08:54
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
File registers "R" use the block switching method. The number of file register points used are divided and specified in units of 32k points. When multiple ... More Details >>
- No:22512
- Release Date:2018/09/03 17:28
- Update:2018/09/20 13:29
- Category: MELSEC-Q Series
-
Maximum number of characters in a comment that can be transferred to a FX3U series
As project data, up to 32 one-byte characters (16 two-byte characters) can be input to each global device comment. However, the maximum number of characters ... More Details >>
- No:24700
- Release Date:2019/02/27 08:59
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
How to change the keeping (latched device data) range (FX3G/FX3GC)
The keeping (latched device data) range is fixed and cannot be changed in parameters. (Reference) [When an optional battery is not used] The keeping ran... More Details >>
- No:22260
- Release Date:2018/08/30 13:48
- Update:2019/02/19 11:52
- Category: MELSEC-F Series , Engineering Software , Main Unit , Accessories
-
Regarding number of CC-Link IE field network Basic connections
When the FX5 CPU Module is used as the master station, the maximum number of devices connected to 1 network is 16. The following firmware versions are requi... More Details >>
- No:44652
- Release Date:2025/03/18 10:22
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Warning 093CH (Home position return data incorrect) occurs when the backup data for absolute position restoration is lost.Execute the machine home position r... More Details >>
-
Minor error 120 occurs in the following case:The zero pass signal (M2406+20n) is OFF when the re-movement to the home position is performed by proximity dog,... More Details >>
-
Regarding the differences between Latches (1) and (2)
Whether the latch range is set by default is different. ・Latch (1) — Latch range is set by default. This can be changed at any time. ・Latch (2) — No latch ... More Details >>
- No:39351
- Release Date:2023/02/15 13:08
- Update:2024/08/19 09:54
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Check if 24 VDC power is supplied to "1A7" (pin No.) of the external input signal connector. More Details >>