FAQ


FAQAbout Products
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Yes. (1) Absolute system (a) When the software stroke limit is invalid Positioning is carried out in a designated direction by "[Cd.40] ABS direction in deg... More Details >>
-
Regarding the function of a special relay.
SM400 and SM8000. ※FX compatible area(SM8000~, SD8000~) is available for the special relay and special device. More Details >>
- No:22288
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:09
- Category: MELSEC iQ-F Series , CPU Module
-
Meanings of the sink input/source input
The sink input connects to a negative common for 24 V DC. The source input connects to a positive common. The sink input is generally used in Japan and No... More Details >>
- No:22254
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , I/O Extension
-
The following shows the procedure for changing the current value to a new value.(1) Write the new current value to "[Cd. 9] New current value".(2) Write "900... More Details >>
-
Programming software and tool for the FX2N-10GM/FX2N-20GM
Use the "FX-PCS-VPS/WIN" software for personal computer or the "E-20TP-SET0" handy programming panel. More Details >>
- No:25014
- Release Date:2019/04/23 11:16
- Category: MELSEC-F Series , Engineering Software , Accessories
-
Regarding how to update the firmware of the FX5 CPU module
FX5U/FX5UC/FX5UJ CPU modules cannot perform firmware update using GX Works3. Use the SD memory card to update the firmware. However, the FX5S CPU module sup... More Details >>
- No:39325
- Release Date:2023/02/14 09:03
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding EtherCAT Communications
The FX5 CPU module does not support EtherCAT communication. There are no products in the FX series or iQ-F series that support EtherCAT communication. More Details >>
- No:39313
- Release Date:2023/02/14 08:54
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Follow the procedure below.(1)Eliminate the error cause.(2) Store the error code to be cleared in SD50.(3)Turn OFF and ON SM50.(4) The error is cleared. More Details >>
- No:22613
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Keyword protection of the MELSEC-F series
The keyword protection cannot be forcibly reset. Since only the keyword that has been registered by theuser is acceptable, please take measures to ensure th... More Details >>
- No:24784
- Release Date:2019/02/27 16:27
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Regarding the differences between CC-Link IE TSN and CC-Link IE Field Networks
(1)Whether or not networks can be mixed on the same trunk line is different. CC-Link IE TSN allows network mixing on the same trunk line. When using a CC-Li... More Details >>
- No:39359
- Release Date:2023/01/12 17:10
- Category: MELSEC iQ-F Series , Network/Communication