The analog input type (temperature/voltage/current) and offset/gain can be set for each channel. More Details >>
- No:24902
- Release Date:2019/04/15 11:31
- Category: MELSEC-F Series , Analog Control
-
The slave stations cannot be assigned to X/Y numbers. Use the auxiliary relay M. More Details >>
- No:24982
- Release Date:2019/04/23 07:21
- Category: MELSEC-F Series , Network/Communication
-
Regarding the COM terminal of the multiple input module
Yes, it's connected internally. More Details >>
- No:39318
- Release Date:2023/01/12 16:54
- Category: MELSEC iQ-F Series , Analog
-
Regarding the communication speed of FX5-CCLGN-MS
The FX5-CCLGN-MS firmware version 1.010 or later supports a communication speed setting of 100 Mbps. More Details >>
- No:39358
- Release Date:2023/01/12 17:09
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding editing device comments in the device usage list
Supported since GX Works3 Ver. 1.095Z, you can edit device comments from the device usage list. More Details >>
- No:40038
- Release Date:2023/08/24 15:44
- Category: MELSEC iQ-F Series , Engineering Software
-
Follow the procedure below to insert a high-speed timer.- Click the Coil button on the toolbar or press the function key F7, then enter "HT[ ] K[ ]".- Click ... More Details >>
- No:22528
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Usage of PIDCONT instruction in process CPU
No. More Details >>
- No:22536
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Boot operation from the standard ROM
The boot operation from the standard ROM is not possible.The program memory of universal model QCPU is a flash ROM.Thus, writing in the program memory achiev... More Details >>
- No:22553
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
How to turn OFF the "COM.ERR" LED of the Ethernet module
The LED can be turned OFF by operations from GX Developer. The operation method is as follows.(1) Connect to the CPU in the standby system in Transfer Setup.... More Details >>
- No:22571
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Cause of file register reset by latch clear operation in universal model QCPU
If Latch (1) is set in the device setting of PLC parameter, the contents of file registers are cleared by latch clear operation. Set Latch (2) to maintain t... More Details >>
- No:22584
- Release Date:2018/09/03 17:29
- Update:2018/09/20 17:31
- Category: MELSEC-Q Series