Regarding the method to connect with multiple devices via Ethernet port
Multiple connections can be established by using a switching hub. More Details >>
- No:22321
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:26
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software , Network/Communication
-
Regarding the built-in analog input/output function
FX5U CPU module has 2 built-in voltage input channels (DC0~10V) and 1 built-in voltage output channel (DC0~10V). If an external resister is connected, the m... More Details >>
- No:22313
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:47
- Category: MELSEC iQ-F Series , CPU Module , Analog
-
Regarding the link refresh settings of FX5-CCL-MS
It is possible to use latch devices or I/O devices (X/Y) for link refresh devices. However, when using I/O devices (X/Y), use I/O numbers (such as X1000 ~/Y... More Details >>
- No:22308
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:37
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software , Network/Communication
-
From the following menu of GX Works3: [Diagnostics]→[Module Diagnostics(CPU Diagnostics)] the event history function can be found. The event history can dis... More Details >>
- No:22305
- Release Date:2018/08/30 13:55
- Update:2023/02/13 11:37
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
The FX5 CPU module does not support UDP broadcast communication. More Details >>
- No:22291
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:49
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Turning on a bit in the data register
In the FX3U/FX3UC series, the bit specification of the data register is possible. (Example) D0.7→7th bit in D0 For the other types of MELSEC-F programmable... More Details >>
- No:22275
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
All input COM terminals send the same signal because all the terminals are internally connected. To turn on the input, the extension unit must be connected ... More Details >>
- No:22274
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , I/O Extension
-
Types of Batteries used in MELSEC-F
F2-40BL: Lithium thionyl chloride primary battery FX2NC-32BL: Lithium thionyl chloride primary battery FX3U-32BL: Manganese dioxide lithium primary battery F... More Details >>
- No:22265
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , Accessories
-
Programmable controllers with no battery (MELSEC-F)
A battery is used for backing up program memory and latched device data and maintaining clock operation in the event of a power failure. The FX3S/FX3G/FX3G... More Details >>
- No:22259
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , Accessories
-
Special auxiliary relay which is always on (MELSEC-F)
M8000 More Details >>
- No:22258
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Engineering Software , Main Unit