FAQ


FAQAbout Products

FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
How to change the keeping (latched device data) range (FX3G/FX3GC)
The keeping (latched device data) range is fixed and cannot be changed in parameters. (Reference) [When an optional battery is not used] The keeping ran... More Details >>
- No:22260
- Release Date:2018/08/30 13:48
- Update:2019/02/19 11:52
- Category: MELSEC-F Series , Engineering Software , Main Unit , Accessories
-
Regarding Control response parameter of built-in PID Control of CPU Module
The control response parameter can set the response to the target value (SV) of PID control as either "normal" or "fast". The difference is as follows. (1)W... More Details >>
- No:44653
- Release Date:2025/03/18 10:23
- Category: MELSEC iQ-F Series , CPU Module , Analog
-
Regarding Device Memory Export/Import
Imports are not supported. Only exports are supported. More Details >>
- No:40027
- Release Date:2023/08/24 14:38
- Category: MELSEC iQ-F Series , Engineering Software
-
Regarding differences between 8 bit and 16 bit modes for non-protocol communication
In 8-bit mode, the upper 8 bits of transmitted and received data are ignored and only the lower 8 bits are valid data. In 16 bit mode, send/receive data i... More Details >>
- No:39363
- Release Date:2023/02/15 13:04
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding Instruction processing time when the program capacity: 128 K steps are set
LD instruction: 0.35 μs, MOV instruction: 0.779 μs. For other instructions, see the manual below. MELSEC iQ-F FX5 Programming Manual (Instructions, Standa... More Details >>
- No:39362
- Release Date:2023/01/12 17:12
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding device comment output to Data Logging Files
Device comments can not be output to data logging files. More Details >>
- No:39321
- Release Date:2023/02/14 09:00
- Category: MELSEC iQ-F Series , CPU Module
-
Counting of a built-in high-speed counter
Check that the RST instruction ofthe high-speed counter is not executed whilethe program is running. Forthe high-speed counter which supports the external r... More Details >>
- No:24787
- Release Date:2019/02/28 09:06
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
FX3U-ENET-ADP connectable programmable controllers in the MELSEC-F series
The FX3U-ENET-ADP can be connected to the FX3G/FX3GC series (both Ver. 2.00 or later) and the FX3U/3UC series (both Ver. 3.10 or later). Products which are ... More Details >>
- No:24706
- Release Date:2019/02/27 09:00
- Category: MELSEC-F Series , Engineering Software , Main Unit , Network/Communication
-
Programing example of heating/cooling control
The following shows an example of heating/cooling control using split control. * For details, refer to the "Programmable Controllers MELSEC PROC... More Details >>
- No:22719
- Release Date:2018/09/03 17:29
- Update:2018/09/21 15:43
- Category: MELSEC-Q Series
-
The Transfer Setup window is displayed in the Navigation window. More Details >>
- No:22579
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
251-260 of Total 1110