FAQ


FAQAbout Products
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
MX Component Version 4's compatibility with the L series CPU
MX Component Version 4 supports the L series CPU. More Details >>
- No:22867
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
GX Works2's compatibility with the ACPU modules
GX Works2 does not support the ACPU modules.Use GX Developer for the ACPU modules.GX Developer is included on the CD-ROM of GX Works2.For the installation pr... More Details >>
- No:22873
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
GX Developer's compatibility with LJ71E71-100
GX Developer does not support LJ71E71-100. Use GX Works2. More Details >>
- No:22911
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Behavior of special relay in offline simulation
The constant scan initial value of GX Simulator is 100 ms. Thus, the value of SM410(0.1sec. clock) is OFF in each scan. To turn ON/OFF SM410, set the consta... More Details >>
- No:22922
- Release Date:2018/09/03 17:30
- Update:2018/09/22 16:39
- Category: Engineering Software
-
About network parameters when building MELSECNET/10 with Q02HCPU-A
Q02(H)CPU-A is the AnUCPU equivalent. When establishing a MELSECNET/10 network, set the refresh parameter with which SB/SW data is transferred to "Y/D" or o... More Details >>
- No:23005
- Release Date:2018/09/03 17:31
- Update:2018/09/26 14:42
- Category: Network related products
-
Difference between networks called CC-Link and those called MELSEC
CC-Link IE, supported by the CC-Link Partner Association, is an open field network standard that integrates networks, from a controller network to field/moti... More Details >>
- No:23013
- Release Date:2018/09/03 17:31
- Category: Network related products
-
T-branch connection and star topology for CC-Link networks
- T-branch T-branch is a connection type that branches one line from a main line. To establish a T-branch CC-Link network, use the repeater module AJ65S... More Details >>
- No:23024
- Release Date:2018/09/03 17:31
- Update:2018/09/26 10:00
- Category: Network related products
-
Receiving data when no receive complete code is designated (QJ71C24N)
Data are received on a received data count basis. If there is no receive complete code and variable length data is received, the data is received at every no... More Details >>
- No:23038
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Duplication error in a CC-Link master station
Possible causes are as follows.(1) Another master station exists on the same line.(2) Noise is detected on the line at power on. More Details >>
- No:23044
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Mixing line topologies with star topologies in the CC-Link IE Field Network
Line topologies and star topologies can be mixed. More Details >>
- No:23059
- Release Date:2018/09/03 17:31
- Category: Network related products
301-310 of Total 1123