FAQ


FAQAbout Products

FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
MX Component Version 3's compatibility with Visual Studio 2010
MX Component Version 3.15R or later supports Visual Basic and Visual C++ of Visual Studio 2010. More Details >>
- No:22543
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Unable to select [Transfer Setup]
If a circuit is being monitored or a monitor window such as the device batch monitor window is open, [Transfer Setup] on the menu is grayed out. Select [Wi... More Details >>
- No:22548
- Release Date:2018/09/03 17:28
- Update:2018/09/20 15:40
- Category: MELSEC-Q Series
-
Auto refresh setting in GX Configurator -MB
Auto refresh setting is for storing the buffer memory data of a MODBUS (R) interface module to specified devices of a CPU module and for storing device data ... More Details >>
- No:22573
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Life expectancy of the CompactFlash card used in the high speed data logger module
The life expectancy is determined by the following calculation.Life expectancy (year) = Total writable size (GB) / 1 year write size (GB/year)For more detail... More Details >>
- No:22592
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Set as follows in the Transfer Setup window. - Select "USB" for "PC side I/F". - Select "GOT" for "PLC side I/F" and select "via GOT (direct coupled) tra... More Details >>
- No:22598
- Release Date:2018/09/03 17:29
- Update:2018/09/20 17:55
- Category: MELSEC-Q Series
-
COMMENT to disappear after a PLC type change
Copy the COMMENT into the MAIN of comments by program before changing the PLC type.The basic model QCPU cannot deal with common comments. More Details >>
- No:22625
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
SNTP communication error in built-in Ethernet port LCPU
The error does not affect the CPU time. The CPU time is not set when a communication error occurs. More Details >>
- No:22783
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Simultaneous broadcast transmission setting for built-in Ethernet port LCPU
To send simultaneous broadcast using UDP, set the parameters as follows.- Destination IP Address: FF.FF.FF.FFh - Destination Port Number: Other than FFFFh (S... More Details >>
- No:22785
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Indication accuracy - Ambient temperature: 25+/-5 degrees Celsius Full scale x (+/-0.3%) - Ambient temperature: 0 to 55degrees Celsius Full scale x (+/-0... More Details >>
- No:22820
- Release Date:2018/09/03 17:30
- Update:2018/09/26 16:51
- Category: MELSEC-L Series
-
Time out error in the communication test of MX Component
The possible causes are as follows. - Incorrect setting with a personal computer or an Ethernet interface module Check the IP address, network number, sta... More Details >>
- No:22934
- Release Date:2018/09/03 17:30
- Update:2018/09/25 09:49
- Category: Engineering Software