Controllers
FAQ within [ Controllers ]
-
Those displayed under COMMENT are common comments, and others are program comments.When there are multiple programs in a project, a common comment applies to... More Details >>
- No:22540
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Difference between C Controller module and programmable controller CPU module
- C Controller module: Programs are created using C and C++ languages. The programs run based on each task and parallel processing of multiple tasks base... More Details >>
- No:22542
- Release Date:2018/09/03 17:28
- Update:2018/09/20 15:05
- Category: MELSEC-Q Series
-
Specification method of high-speed timer
To use a high-speed timer, insert a circuit of application instruction such as "OUTH T0 K100". More Details >>
- No:22549
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Reading file registers in the standard RAM
Set Target Memory to "Standard RAM" in the Read from PLC window to select a file register file. More Details >>
- No:22552
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Boot operation from the standard ROM
The boot operation from the standard ROM is not possible.The program memory of universal model QCPU is a flash ROM.Thus, writing in the program memory achiev... More Details >>
- No:22553
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Compatibility with 64-bit Windows 7
GX Works2 Version 1.62Q or later supports Windows 7. More Details >>
- No:22554
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Corrective action when the program size exceeds the capacity
If comments and symbolic information are stored in the program memory, write them in the standard ROM. More Details >>
- No:22560
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
How to read device data and file registers in Q series
Specify the target memory in the Read from PLC window and execute reading. More Details >>
- No:22564
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Recommended cables for MODBUS(R) interface module QJ71MB91
The RS-232 cable should meet RS-232 standards and not exceed 15 m in length.The RS-422/485 cable should meet specifications described in the following manual... More Details >>
- No:22566
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
How to turn OFF the "COM.ERR" LED of the Ethernet module
The LED can be turned OFF by operations from GX Developer. The operation method is as follows.(1) Connect to the CPU in the standby system in Transfer Setup.... More Details >>
- No:22571
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series