It cannot. Because there will be two CC-link IE field network Basic master stations in a network. More Details >>
- No:39346
- Release Date:2023/02/15 10:05
- Update:2024/04/25 10:10
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding CC-Link IE Field Network Basic Refresh Settings
You can't. Device allocation for refresh settings is sequential only. More Details >>
- No:39306
- Release Date:2023/02/13 16:41
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding the HOLD/CLEAR function of the built-in analog output
This function allows you to select the digital value to perform D/A conversion from the following three patterns depending on the operating status of the CPU... More Details >>
- No:39289
- Release Date:2023/01/12 16:51
- Category: MELSEC iQ-F Series , CPU Module , Analog
-
The slave stations cannot be assigned to X/Y numbers. Use the auxiliary relay M. More Details >>
- No:24982
- Release Date:2019/04/23 07:21
- Category: MELSEC-F Series , Network/Communication
-
Model of the cable provided with the FX2N series extension unit
The model of the cable isFX0N-5EC. More Details >>
- No:24968
- Release Date:2019/04/23 07:19
- Category: MELSEC-F Series , Main Unit , I/O Extension
-
Replacement of the fuse in the FX programmable controller
Customers cannot replace the fuse. For the replacement, please consult your local Mitsubishi representative. More Details >>
- No:24909
- Release Date:2019/04/15 11:30
- Category: MELSEC-F Series , Main Unit
-
If the OUT instruction using the device number of the latch target device exists in a sequence program, the latched data may be overwritten by execution of t... More Details >>
- No:24783
- Release Date:2019/02/27 16:16
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Insufficient memory capacity for sequence programs
It cannot be increased by installing an SRAM card. The size of executable program depends on the program memory size of the CPU. Use another CPU of which p... More Details >>
- No:22578
- Release Date:2018/09/03 17:29
- Update:2018/09/20 17:09
- Category: MELSEC-Q Series
-
How to copy comments from GX Developer to GX Works2
Launch GX Works2, select [Project] -> [Open Other Project], and read the data created with GX Developer. Copy the comment from the list of device comme... More Details >>
- No:22526
- Release Date:2018/09/03 17:28
- Update:2018/09/20 14:32
- Category: MELSEC-Q Series
-
How to check the scan time with GX Works3
You can check the processing time and scan time of the program currently being executed in "Program List Monitor". [Online] -> [Monitor] -> [Program... More Details >>
- No:22458
- Release Date:2018/09/03 17:28
- Update:2018/09/19 11:51
- Category: MELSEC iQ-R Series