The following Diatrend cable can be used.- DQ-U2 More Details >>
- No:22623
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Compatibility between the A series modules and Q series modules
When an ACPU module is replaced with a QCPU module, programs for the ACPU module can be used by changing the PLC type in GX Developer. However, the programs ... More Details >>
- No:22696
- Release Date:2018/09/03 17:29
- Update:2018/09/21 14:21
- Category: MELSEC-Q Series
-
Data communications between programmable controllers
Any data can be sent and received if the socket communication function instructions are used. More Details >>
- No:22702
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
How to specify intelligent function module devices
For "U**", set the first two digits of the start I/O number of an intelligent function module in three-digit representation.Example) For X/Y1F0, set "U1F". More Details >>
- No:22704
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
SD memory cards used for Q24DHCCPU-V
Mitsubishi Electric's SD memory cards, which can be installed into Q24DHCCPU-V, are shown below. - NZ1MEM-2GBSD (memory capacity: 2Gbytes) - NZ1MEM-4GBSD (... More Details >>
- No:22711
- Release Date:2018/09/03 17:29
- Update:2018/09/22 08:58
- Category: MELSEC-Q Series
-
SNTP communication error in built-in Ethernet port LCPU
The error does not affect the CPU time. The CPU time is not set when a communication error occurs. More Details >>
- No:22783
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Simultaneous broadcast transmission setting for built-in Ethernet port LCPU
To send simultaneous broadcast using UDP, set the parameters as follows.- Destination IP Address: FF.FF.FF.FFh - Destination Port Number: Other than FFFFh (S... More Details >>
- No:22785
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Causes to why SD1286 does not turn on during socket communication of LCPU
Check the following. - Whether the external device specifies the port number of the corresponding connection to the L series CPU. - In the TCP fixed-length... More Details >>
- No:22787
- Release Date:2018/09/03 17:30
- Update:2018/09/22 11:51
- Category: MELSEC-L Series
-
The minimum input response times are different. The minimum input response time is 100 microseconds for standard inputs, and 10 microseconds for high-speed i... More Details >>
- No:22804
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Statements of GX Works2 and the scan time
The input method for statements, either "PLC" or "Peripheral", makes a difference. - If "PLC" is set for statements, they are written into the program mem... More Details >>
- No:22856
- Release Date:2018/09/03 17:30
- Update:2018/09/22 14:18
- Category: Engineering Software