FAQ
FAQAbout Products
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
How to make the expanded cyclic setting for CC-Link local stations
Make the expanded cyclic setting for a CC-Link local station using the programming tool, GX Developer or GX Works2. Follow the procedure below. (1) Set th... More Details >>
- No:23030
- Release Date:2018/09/03 17:31
- Update:2018/09/26 10:17
- Category: Network related products
-
Difference between networks called CC-Link and those called MELSEC
CC-Link IE, supported by the CC-Link Partner Association, is an open field network standard that integrates networks, from a controller network to field/moti... More Details >>
- No:23013
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Buffer memory addresses of CC-Link modules
If the remote net Ver.1 mode is used, each station number is given fixed buffer memory addresses.If the remote net Ver.2 mode is used, different buffer memor... More Details >>
- No:22992
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Programming for FX programmable controllers in ST language
You can create a program with "GX Works2" of MELSOFT applications. More Details >>
- No:22960
- Release Date:2018/09/03 17:31
- Category: Engineering Software
-
Copying device comments in GX Works2
Select a device comment in the project view and select "Copy" from the right-click menu. More Details >>
- No:22950
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
How to copy a comment in GX Works2
1. Right-click the file name of a device comment to be copied, and select "Copy" from the menu.2. Right-click the file name of a device comment to which the ... More Details >>
- No:22939
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Compatibility between the Japanese and English versions of GX Developer
All the components other than comments in Japanese are supported. Ladder programs and parameters can be used as they are, whether or not they are created usi... More Details >>
- No:22848
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
The error code "2110" is "SP.UNIT ERROR.". This error may be caused by one of the following factors.(1) The module that has been specified by a FROM/TO instr... More Details >>
- No:22830
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Yes. As a guide, the processing time is shown below.For the logging condition, refer to figure 1 below. - For 16 devices: 2 ms - For 64 devices: 6 ms More Details >>
- No:22829
- Release Date:2018/09/03 17:30
- Update:2018/09/22 15:33
- Category: MELSEC-L Series
-
RS-232 adapter cable disconnection prevention
Yes. More Details >>
- No:22799
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
411-420 of Total 1055