Input numbers of the FX programmable controllers
Since they are octal, the number after X7 is X10 and after X77 is X100. More Details >>
- No:25000
- Release Date:2019/04/23 10:39
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Target address change during the positioning operation in the FX3U-1PG
Yes, it is possible. Set a new value for the target address to the target address change value (BFM#54, #53) during the positioning operation. * The targ... More Details >>
- No:24986
- Release Date:2019/04/23 07:22
- Category: MELSEC-F Series , Positioning Control
-
Analog input modules that can be used in the FX3G series
The FX3G-2AD-BD (2-channel analog input expansion board), FX3U-4AD-ADP (4-channel analog input special adapter), and FX3U-3A-ADP (2-channel analog input/1-ch... More Details >>
- No:24960
- Release Date:2019/04/23 07:17
- Category: MELSEC-F Series , Analog Control
-
Number of extension cables that can be used per system
One extension cable can be used per system. Two or more extension cables cannot be used. More Details >>
- No:24958
- Release Date:2019/04/18 14:33
- Category: MELSEC-F Series
-
Maximum number of personal computers that can be communicated with the FX3U-ENET-L simultaneously
For communications using MELSOFT connection, such as GX Developer, GX Works2, GOT1000, and MX Component, up to two personal computers can be used. In additi... More Details >>
- No:24920
- Release Date:2019/04/17 11:41
- Category: MELSEC-F Series , Network/Communication
-
Minor error 197AH (Home position return zero not passed) occurs in the following case:"[St.1066] zero pass" is OFF when the re-movement to the home position ... More Details >>
- No:23560
- Release Date:2018/09/14 15:09
- Category: RnMTCPU
-
Transient transmission of the CC-Link IE Controller
Transient transmission is a function that allows communication with programmable controllers in other stations. Communication with programmable controllers i... More Details >>
- No:23016
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Clearing data in the QJ71C24N's receiving area buffer memory
Receiving data overwrites the buffer memory data. Writing 0 with a program can be performed but is unnecessary as the data is overwritten. More Details >>
- No:23009
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Executing the QJ71C24N's pre-defined protocol support function
Executing the CPRTCL instruction (dedicated instruction) executes a specified protocol. More Details >>
- No:23004
- Release Date:2018/09/03 17:31
- Category: Network related products
-
PLC parameter setting for QJ61BT11N
If the Network Parameter is used, CC-Link communication does not need the Select setting in the I/O assignment setting of the PLC parameter.If the parameter ... More Details >>
- No:23002
- Release Date:2018/09/03 17:31
- Category: Network related products