The error code "2401" is "FILE SET ERROR". The individual information parameter number "1100H" corresponds to a file register. The cause of the error is that... More Details >>
- No:22797
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
The data logging file transfer function allows for transfer of the logging data to an upper server regularly. It is transferred when data logging is switched... More Details >>
- No:22741
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Set as follows in the Transfer Setup window. - Select "USB" for "PC side I/F". - Select "GOT" for "PLC side I/F" and select "via GOT (direct coupled) tra... More Details >>
- No:22598
- Release Date:2018/09/03 17:29
- Update:2018/09/20 17:55
- Category: MELSEC-Q Series
-
It is an embedded RTOS (real-time OS) developed by Wind River, which is proven worldwide as reliable and stable.The version of the operation system installed... More Details >>
- No:22544
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
GX Simulator in GX Works2 disk
The simulation function is included in GX Works2.For more details of the functions of GX Work2, refer to GX Works2 Version 1 Operating Manual (Common). More Details >>
- No:22537
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Difference between GX Works2 and GX Works
GX Works2 is programmable controller engineering software integrating programming and simulation of programmable controller and setting monitor tool functio... More Details >>
- No:22505
- Release Date:2018/09/03 17:28
- Update:2018/09/20 13:16
- Category: MELSEC-Q Series
-
Software to be supplied with GX Works3
GX Works2 and GX Developer are supplied with GX Works3. When installing GX Works3, you can select whether to install GX Works2 and GX Developer together. More Details >>
- No:22463
- Release Date:2018/09/03 17:28
- Update:2018/09/18 16:14
- Category: MELSEC iQ-R Series
-
Regarding KeepAlive for SLMP Communication
For TCP protocol of SLMP communication, KeepAlive is fixed and cannot be changed. In the case of UDP protocol, it is fixed to not perform a keep-alive check. More Details >>
- No:45477
- Release Date:2025/11/12 13:37
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding the Mark detection function
The Mark detection function of the FX5-40/80SSC-G is supported by the Touch probe function of the MX-F Model. More Details >>
- No:44988
- Release Date:2025/05/08 09:09
- Category: MELSEC MX Controller MX-F Model
-
Regarding replacement from 128 point type of FX3U
The FX5U CPU module has a lineup of up to 80 point. The following configuration is recommended when replacing the FX3U-128MR/ES. Recommended alternative (1... More Details >>
- No:44617
- Release Date:2024/11/28 16:13
- Category: MELSEC iQ-F Series , CPU Module