FAQ


FAQAbout Products

FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Writing comments into a programmable controller
Make a space for comments in the parameter setting of the programmable controller with GX Developer.To write the created comments into a programmable control... More Details >>
- No:22962
- Release Date:2018/09/03 17:31
- Category: Engineering Software
-
MODE switch setting for QJ61BT11N
The MODE switch can set the following modes.- 0 to 4: Online mode- 5 to 9: Line test mode- A to E: Hardware test modeEach mode in ascending order of set valu... More Details >>
- No:23025
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Connecting QJ71C24N to an external device that has no DTR signal
Carry out DTR and DSR wiring that returns signals on QJ71C24N(-R2). More Details >>
- No:23039
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Terminal blocks for the MELSEC-F series
Whether the terminal block is removable or not differs depending on the series. Types of the terminal blocks for the MELSEC-F series main units are as follow... More Details >>
- No:24774
- Release Date:2019/02/27 15:34
- Category: MELSEC-F Series , Main Unit
-
Connecting local stations to the FX3U-16CCL-M
No, local stations cannot be connected to the FX3U-16CCL-M. Remote I/O stations, remote device stations, and intelligent device stations can be connected to... More Details >>
- No:24791
- Release Date:2019/02/28 09:06
- Category: MELSEC-F Series , Network/Communication
-
The FX3U-ENET-ADP does not support the DHCP function. Set the fixed IP address using the parameter setting of GX Works2. On GX Works2, select "Parameter" and... More Details >>
- No:24870
- Release Date:2019/04/15 08:05
- Category: MELSEC-F Series , Network/Communication
-
Latched (battery backed) area in the data register (D) of the FX3G/FX3GC series
D128 to D1099 are the latched device area. D1100 to D7999 can be changed to latched (battery backed) type devices by installing an optional battery and setti... More Details >>
- No:24901
- Release Date:2019/04/15 11:31
- Category: MELSEC-F Series , Main Unit
-
Differences in the specifications between the programmable controllers used in Japan and overseas.
The input signal forms are different. All the programmable controllers for the domestic market other than the FX3G/FX3U series are the sink input. The progra... More Details >>
- No:24913
- Release Date:2019/04/17 11:39
- Category: MELSEC-F Series , Main Unit
-
Adding two channels of the RS-232C port in the FX3G series
Select the 40-point or 60-point type FX3G series main unit. In this case, two FX3G-232-BDs can be connected. When FX3G-CNV-ADP is used, anFX3U-232ADP can be ... More Details >>
- No:24926
- Release Date:2019/04/17 11:42
- Category: MELSEC-F Series , Main Unit
-
Overwriting a current value with the high-speed counter comparison instruction
The output contact is activated according to the change of the current value register along with the counting input. Therefore, the value changed by executin... More Details >>
- No:24931
- Release Date:2019/04/17 11:43
- Category: MELSEC-F Series , Main Unit
641-650 of Total 1108